Meander Resonator Coupled UHF RFID System for Biomechanics Sensing Applications

This paper presents a biomechanics sensing system based on an ultra-high frequency (UHF) RFID tag coupled with a meander resonator for motion tracking and displacement sensing. The variations in their relative position alter the strength of mutual coupling, leading to impedance changes in the RFID tag antenna. These impedance variations modulate the power reflection coefficient, which in turn affects both the backscattered signal strength (RSSI) and the turn-on threshold power of the RFID tag. The performance of the system was evaluated through simulations and experimental validation, demonstrating a 14 dB reduction in RSSI and a 5 dBm increase in threshold power over a displacement range of 30 mm. The system was further validated for wearable movement sensing in knee flexion tracking, where results indicated an RSSI variation of around 12 dB as the knee angle changed from 115∘ to 175∘. Additionally, the turn-on threshold power ( Pth ) exhibited a strong correlation with knee flexion angles, achieving a coefficient of determination ( R2 = 0.973 ) based on curve-fitted data. These results validate the feasibility of the proposed system for wearable body motion monitoring in healthcare applications.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Radio Frequency Identification
Published
2025-01-01
DOI
https://doi.org/10.1109/jrfid.2025.3570441
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Meander Resonator Coupled UHF RFID System for Biomechanics Sensing Applications

Raúl Fernández‐García, Ignacio Gil, Tauseef Hussain
IEEE Journal of Radio Frequency Identification
Wireless Body Area Networks
article

Meander Resonator Coupled UHF RFID System for Biomechanics Sensing Applications

Raúl Fernández‐García, Ignacio Gil, Tauseef Hussain
article en

Abstract

This paper presents a biomechanics sensing system based on an ultra-high frequency (UHF) RFID tag coupled with a meander resonator for motion tracking and displacement sensing. The variations in their relative position alter the strength of mutual coupling, leading to impedance changes in the RFID tag antenna. These impedance variations modulate the power reflection coefficient, which in turn affects both the backscattered signal strength (RSSI) and the turn-on threshold power of the RFID tag. The performance of the system was evaluated through simulations and experimental validation, demonstrating a 14 dB reduction in RSSI and a 5 dBm increase in threshold power over a displacement range of 30 mm. The system was further validated for wearable movement sensing in knee flexion tracking, where results indicated an RSSI variation of around 12 dB as the knee angle changed from 115∘ to 175∘. Additionally, the turn-on threshold power ( Pth ) exhibited a strong correlation with knee flexion angles, achieving a coefficient of determination ( R2 = 0.973 ) based on curve-fitted data. These results validate the feasibility of the proposed system for wearable body motion monitoring in healthcare applications.

IEEE Journal of Radio Frequency IdentificationVol. 9
Universitat Politècnica de Catalunya (ES)
Ministerio de Ciencia e Innovación
Affordable and clean energy
Openalex Percentile: Top 90%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.