STRAS: a new high-time-resolution aerosol sampler for particle-induced X-ray emission (PIXE) analysis

Abstract. The joint use of hourly resolution sampling and analyses with accelerated ion beams such as with the particle-induced X-ray emission (PIXE) technique has allowed the measurement of hourly temporal patterns of particulate matter (PM) composition at many sites in different parts of the world. The demand within the scientific community for this type of analysis has been continuously increasing in recent years, but hourly resolution samplers suitable for PIXE analysis have been discontinued and/or suffer from some technical limitations. In this framework, a new hourly sampler, STRAS (Size- and Time-Resolved Aerosol Sampler), was developed for the collection of PM10, PM2.5 or PM1. It allows automatic sequential sampling of up to 168 hourly samples (1 week), and it is mechanically robust, compact and easily transportable. To increase PIXE sensitivity, each sample is concentrated on a small surface area on a polycarbonate membrane. Comparison between the elemental concentrations retrieved by STRAS samples and samples collected using a standard sequential sampler operated in parallel shows very good agreement; indeed, if both the samplers use the same kind of membrane, the concentrations of all detected elements are in agreement within 10 %.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-05-16
DOI
https://doi.org/10.5194/amt-18-2137-2025
Citations
2
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STRAS: a new high-time-resolution aerosol sampler for particle-induced X-ray emission (PIXE) analysis

Cosimo Fratticioli, Federica Crova, S. Nava, Alice Forello et al.
2 citations
Atmospheric measurement techniques
X-ray Spectroscopy and Fluorescence Analysis
3.77
article

STRAS: a new high-time-resolution aerosol sampler for particle-induced X-ray emission (PIXE) analysis

Cosimo Fratticioli, Federica Crova, S. Nava, Alice Forello, R. Vecchi, G. Valli, Giulia Calzolai, Marco Manetti, M. Chiari, Federico Mazzei, F. Lucarelli, P. Prati, Dario Massabò, Carlo Cialdai, Vera Bernardoni, L. Carraresi, Luca Repetto, Virginia Vernocchi, Fabio Giardi, Laura Cadeo
article en
2 citations

Abstract

Abstract. The joint use of hourly resolution sampling and analyses with accelerated ion beams such as with the particle-induced X-ray emission (PIXE) technique has allowed the measurement of hourly temporal patterns of particulate matter (PM) composition at many sites in different parts of the world. The demand within the scientific community for this type of analysis has been continuously increasing in recent years, but hourly resolution samplers suitable for PIXE analysis have been discontinued and/or suffer from some technical limitations. In this framework, a new hourly sampler, STRAS (Size- and Time-Resolved Aerosol Sampler), was developed for the collection of PM10, PM2.5 or PM1. It allows automatic sequential sampling of up to 168 hourly samples (1 week), and it is mechanically robust, compact and easily transportable. To increase PIXE sensitivity, each sample is concentrated on a small surface area on a polycarbonate membrane. Comparison between the elemental concentrations retrieved by STRAS samples and samples collected using a standard sequential sampler operated in parallel shows very good agreement; indeed, if both the samplers use the same kind of membrane, the concentrations of all detected elements are in agreement within 10 %.

Atmospheric measurement techniquesVol. 18(9)
University of Milan (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Firenze (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Milano (IT), University of Florence (IT), National Cancer Research Institute (GB), University of Genoa (IT)
Ministero dell’Istruzione, dell’Università e della Ricerca, Fondazione Cassa di Risparmio di Firenze, Instituto Nazionale di Fisica Nucleare, Nuclear Physics
Openalex Percentile: Top 8%
X-ray Spectroscopy and Fluorescence Analysis
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.