Quantification of Respirable Dust Concentration at an Underground Copper Mine Using a Personal Optical Particle Counter

Exposure assessments are conducted using standardized gravimetric sampling (SGS) methodologies. However, the gravimetric analysis of respirable dust (RD) provides only one data point. Based on this background, this study aims to quantify RD concentration and peak RD exposure detected as time-series data using a personal optical particle counter (OPC) for possible applications of exposure monitoring in near-real time. Thirty pairs of side-by-side RD exposure samples were collected (22 personal and 8 static) using the Nanozen DustCount 9000Z1 OPC and SGS (NIOSH 0600). The SGS samples were sent for gravimetric analysis in an ISO 17025:2005-accredited analytical laboratory. A correction equation for the OPC sensor was established using linear regression and was used to correct the RD concentrations that were quantified by the OPC. The RD concentrations quantified by the OPC sensor were strongly correlated with those of the SGS method (r = 0.93), and the Bland-Altman analysis showed a consistent pattern and that, on average, the SGS method measured 0.27 mg/m3 higher than the OPC sensor. The time-weighted average RDopc concentrations were less than 1.5 mg/m3 for the mine sections sampled; the highest peak RDopc concentration was 11.51 mg/m3. The results from the side-by-side sampling showed a consistently positive bias, and the Pearson correlation was strong. Thus, the results from Nanozen DustCount 9000Z1 could be corrected using the SGS results and linear regression. The corrected RD concentration can be used to assess the efficacy of the engineering controls in-time. The exposure data from the OPC complement the SGS results by providing additional exposure data such as peak exposure and particle size distribution. From the corrected RD exposure data, the RCS was estimated. Based on the results of this estimate, there is potential for overexposure to RCS at this mine; thus, miners are likely to develop silicosis.

Authors

Institutions

Publication Details

Journal
ACS Chemical Health & Safety
Published
2025-05-15
DOI
https://doi.org/10.1021/acs.chas.5c00037
Citations
2
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
1.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Respirable Dust Concentration at an Underground Copper Mine Using a Personal Optical Particle Counter

N. K. Mumba, Joseph Simfukwe, Stephanus J. L. Linde, Masilu Daniel Masekameni et al.
2 citations
ACS Chemical Health & Safety
Air Quality Monitoring and Forecasting
1.60
article

Quantification of Respirable Dust Concentration at an Underground Copper Mine Using a Personal Optical Particle Counter

N. K. Mumba, Joseph Simfukwe, Stephanus J. L. Linde, Masilu Daniel Masekameni, Patrick Hayumbu, Mwaba Sifanu, Lubinda Nabiwa
article en
2 citations

Abstract

Exposure assessments are conducted using standardized gravimetric sampling (SGS) methodologies. However, the gravimetric analysis of respirable dust (RD) provides only one data point. Based on this background, this study aims to quantify RD concentration and peak RD exposure detected as time-series data using a personal optical particle counter (OPC) for possible applications of exposure monitoring in near-real time. Thirty pairs of side-by-side RD exposure samples were collected (22 personal and 8 static) using the Nanozen DustCount 9000Z1 OPC and SGS (NIOSH 0600). The SGS samples were sent for gravimetric analysis in an ISO 17025:2005-accredited analytical laboratory. A correction equation for the OPC sensor was established using linear regression and was used to correct the RD concentrations that were quantified by the OPC. The RD concentrations quantified by the OPC sensor were strongly correlated with those of the SGS method (r = 0.93), and the Bland-Altman analysis showed a consistent pattern and that, on average, the SGS method measured 0.27 mg/m3 higher than the OPC sensor. The time-weighted average RDopc concentrations were less than 1.5 mg/m3 for the mine sections sampled; the highest peak RDopc concentration was 11.51 mg/m3. The results from the side-by-side sampling showed a consistently positive bias, and the Pearson correlation was strong. Thus, the results from Nanozen DustCount 9000Z1 could be corrected using the SGS results and linear regression. The corrected RD concentration can be used to assess the efficacy of the engineering controls in-time. The exposure data from the OPC complement the SGS results by providing additional exposure data such as peak exposure and particle size distribution. From the corrected RD exposure data, the RCS was estimated. Based on the results of this estimate, there is potential for overexposure to RCS at this mine; thus, miners are likely to develop silicosis.

ACS Chemical Health & SafetyVol. 32(3)
University of South Africa (ZA), University of the Witwatersrand (ZA), North-West University (ZA), Copperbelt University (ZM), Faculty of Public Health (GB)
World Bank Group, Copperbelt University
Openalex Percentile: Top 18%
Air Quality Monitoring and Forecasting
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.