Numerical analysis and experimental research on Acoustic-vibration characteristic of 110 kV transformer tank

A vibroacoustic coupling model of the 110 kV transformer tank is constructed by using the finite element method. The structural vibration response under 100 Hz and 200 Hz sound source excitation is analyzed. Radiated sound field characteristics and sound transmission loss performance across the 0-400 Hz frequency range are evaluated. Then, a test system is established to measure vibration response and sound transmission loss through experiments. Simulation analysis and experimental test results show that the average sound transmission loss of the 110 kV transformer tank ranges from 30 dB to 40 dB. The simulation calculation results show good agreements with experimental test results, which prove the correctness of the vibroacoustic coupling model of the 110 kV transformer tank.

Authors

Publication Details

Journal
Vibroengineering PROCEDIA
Published
2025-05-15
DOI
https://doi.org/10.21595/vp.2025.24921
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis and experimental research on Acoustic-vibration characteristic of 110 kV transformer tank

Xiaolong Wei, Ning Qiu, Gang Du, Jiangang Ma et al.
Vibroengineering PROCEDIA
Noise Effects and Management
article

Numerical analysis and experimental research on Acoustic-vibration characteristic of 110 kV transformer tank

Xiaolong Wei, Ning Qiu, Gang Du, Jiangang Ma, Zhao Yalin, Song Wenjin
article en

Abstract

A vibroacoustic coupling model of the 110 kV transformer tank is constructed by using the finite element method. The structural vibration response under 100 Hz and 200 Hz sound source excitation is analyzed. Radiated sound field characteristics and sound transmission loss performance across the 0-400 Hz frequency range are evaluated. Then, a test system is established to measure vibration response and sound transmission loss through experiments. Simulation analysis and experimental test results show that the average sound transmission loss of the 110 kV transformer tank ranges from 30 dB to 40 dB. The simulation calculation results show good agreements with experimental test results, which prove the correctness of the vibroacoustic coupling model of the 110 kV transformer tank.

Vibroengineering PROCEDIAVol. 58
State Grid Corporation of China, Science and Technology Project of State Grid
Openalex Percentile: Top 86%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical analysis and experimental research on Acoustic-vibration characteristic of 110 kV transformer tank — Xiaolong Wei, Ning Qiu, et al. · Vibroengineering PROCEDIA (2025) | TGRS Research Map | TGRS