Electron noise analysis of the Wolter-I X-ray telescope based on Monte Carlo simulation

To investigate bremsstrahlung radiation generated when the multi-layer nested Wolter-I X-ray telescope is bombarded by a high-energy electron stream, a simulation analysis using the Monte Carlo simulation software MCNP was performed to study this process (the mirror reflective film materials: Ir and Au). According to the simulation results, we found that the change of the electron incident angle has a negligible impact on the yield of the noise X-ray photons. When the incident electron energy is less than 40 keV, the energy of the generated X-ray photons is concentrated in a range below 15 keV, and the yield of noise X-ray photons is lower than the order of 10 −6 , which has little effect on the optical performance of the telescope.

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America B
Published
2025-05-15
DOI
https://doi.org/10.1364/josab.559649
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electron noise analysis of the Wolter-I X-ray telescope based on Monte Carlo simulation

pengfei qiang, Linsen Li, Jingjing Zeng
Journal of the Optical Society of America B
Advanced X-ray Imaging Techniques
article

Electron noise analysis of the Wolter-I X-ray telescope based on Monte Carlo simulation

pengfei qiang, Linsen Li, Jingjing Zeng
article en

Abstract

To investigate bremsstrahlung radiation generated when the multi-layer nested Wolter-I X-ray telescope is bombarded by a high-energy electron stream, a simulation analysis using the Monte Carlo simulation software MCNP was performed to study this process (the mirror reflective film materials: Ir and Au). According to the simulation results, we found that the change of the electron incident angle has a negligible impact on the yield of the noise X-ray photons. When the incident electron energy is less than 40 keV, the energy of the generated X-ray photons is concentrated in a range below 15 keV, and the yield of noise X-ray photons is lower than the order of 10 −6 , which has little effect on the optical performance of the telescope.

Journal of the Optical Society of America BVol. 42(6)
Xi'an Institute of Optics and Precision Mechanics (CN)
Affordable and clean energy
Openalex Percentile: Top 88%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.