Direct Microplate Sampling Mass Spectrometry for High-Throughput Screening of Biocatalytic Activity

The development of biocatalysis depends heavily on high-throughput screening (HTS) approaches to uncover engineered enzymes with superior biocatalytic activity. Recent advances in mass spectrometry (MS) enable label-free, high-speed analysis of biocatalytic samples in standard microplates by omitting the chromatographic separation. However, most MS methods need a complicated sampling interface system and face challenges due to biological matrix interferences, which can diminish the sensitivity and reliability. Herein, we established a direct microplate sampling (DMS)-MS technique for HTS of the enzymatic activity of 17β-hydroxysteroid dehydrogenase (17β-HSD) in steroid biocatalysis. The implementation of an open port interface (OPI) probe with a customized ion source for microwell direct insertion sampling and ionization has streamlined the setup, reduced operational complexity, and shortened the analysis time to 0.9-6.5 s/sample. A sample preparation strategy involving derivatization, followed by high-ratio dilution (e.g., 10,000-fold), was further integrated prior to DMS-MS for mitigating ion suppression effects across diverse biological matrices. Ultimately, this workflow, when applied for monitoring multiple steroids in 17β-HSD biocatalytic processes, demonstrated high stability (peak area RSDs < 7%), minimal carryover (<1%), and quantitative accuracy comparable to conventional liquid chromatography (LC) experiments while providing a >150-fold throughput enhancement. After screening a total of 5760 17β-HSD mutants across three different steroid conversion reactions, we identified and verified two new variants with enhanced biocatalytic activities. This study successfully established a DMS-MS-based HTS workflow for microplate screening, providing a simplified, robust, and highly reliable analytical platform for microbial or enzyme engineering projects involving complex biological matrices.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-05-15
DOI
https://doi.org/10.1021/acs.analchem.5c00267
Citations
4
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Microplate Sampling Mass Spectrometry for High-Throughput Screening of Biocatalytic Activity

Y Wang, Wen Zhang, Jingfang Sun, Long Chen et al.
4 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
3.03
article

Direct Microplate Sampling Mass Spectrometry for High-Throughput Screening of Biocatalytic Activity

Y Wang, Wen Zhang, Jingfang Sun, Long Chen, Shuai Guo, Mengqian Jia
article en
4 citations

Abstract

The development of biocatalysis depends heavily on high-throughput screening (HTS) approaches to uncover engineered enzymes with superior biocatalytic activity. Recent advances in mass spectrometry (MS) enable label-free, high-speed analysis of biocatalytic samples in standard microplates by omitting the chromatographic separation. However, most MS methods need a complicated sampling interface system and face challenges due to biological matrix interferences, which can diminish the sensitivity and reliability. Herein, we established a direct microplate sampling (DMS)-MS technique for HTS of the enzymatic activity of 17β-hydroxysteroid dehydrogenase (17β-HSD) in steroid biocatalysis. The implementation of an open port interface (OPI) probe with a customized ion source for microwell direct insertion sampling and ionization has streamlined the setup, reduced operational complexity, and shortened the analysis time to 0.9-6.5 s/sample. A sample preparation strategy involving derivatization, followed by high-ratio dilution (e.g., 10,000-fold), was further integrated prior to DMS-MS for mitigating ion suppression effects across diverse biological matrices. Ultimately, this workflow, when applied for monitoring multiple steroids in 17β-HSD biocatalytic processes, demonstrated high stability (peak area RSDs < 7%), minimal carryover (<1%), and quantitative accuracy comparable to conventional liquid chromatography (LC) experiments while providing a >150-fold throughput enhancement. After screening a total of 5760 17β-HSD mutants across three different steroid conversion reactions, we identified and verified two new variants with enhanced biocatalytic activities. This study successfully established a DMS-MS-based HTS workflow for microplate screening, providing a simplified, robust, and highly reliable analytical platform for microbial or enzyme engineering projects involving complex biological matrices.

Analytical ChemistryVol. 97(22)
China Pharmaceutical University (CN)
Openalex Percentile: Top 9%
Mass Spectrometry Techniques and Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.