This study investigates transient heat transfer in the oral cavity under varying conditions using a finite element model combined with corresponding experiments. By modeling and measuring oral temperature during cold liquid intake, temperature recovery, and prolonged cold air inhalation, this study examines both temperature distribution across different oral regions and transient thermal dynamics. Results reveal that anterior teeth exhibit greater thermal sensitivity and slower temperature recovery following cold exposure, while posterior regions maintain higher and more stable temperatures. Additionally, buccal surfaces consistently show higher and more stable temperatures than lingual surfaces, underscoring the importance of measurement location for accuracy. The simulation demonstrated moderate agreement with experimental data, achieving a mean absolute error (MAE) of 3.39 °C (13.46%) for upper facial positions and 2.91 °C (10.35%) for lower facial positions during cold liquid intake scenarios. Furthermore, a strong correlation was observed between core body temperature and regional oral temperatures during prolonged cold air inhalation. While the total duration of mouth breathing significantly affects oral temperature, variations in respiratory cycle frequency showed minimal impact on thermal response. These findings provide important guidance for the development of non-invasive core temperature estimation methods based on oral biosensors. In particular, they offer insights for optimizing sensor placement in thermally stable regions and designing data-driven calibration algorithms capable of compensating for transient environmental disturbances, thereby enhancing the accuracy and reliability of wearable biosensing systems in dynamic conditions. • A computational model simulates oral temperature under various conditions. • Front teeth show slower temperature recovery and greater fluctuation. • Buccal surfaces maintain higher, more stable temperatures than lingual surfaces. • Oral cavity temperature returns to near core temperature within 15 minutes after cold exposure. • Respiratory rate has minimal impact on oral temperature during breathing.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-05-15
DOI
https://doi.org/10.1016/j.rineng.2025.105284
Citations
2
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational and experimental study of thermal behavior in the oral cavity for biosensing applications

Jeroen Bergmann, Yuanzhe Zhao
2 citations
Results in Engineering
Infrared Thermography in Medicine
2.72
article

Computational and experimental study of thermal behavior in the oral cavity for biosensing applications

Jeroen Bergmann, Yuanzhe Zhao
article en
2 citations

Abstract

This study investigates transient heat transfer in the oral cavity under varying conditions using a finite element model combined with corresponding experiments. By modeling and measuring oral temperature during cold liquid intake, temperature recovery, and prolonged cold air inhalation, this study examines both temperature distribution across different oral regions and transient thermal dynamics. Results reveal that anterior teeth exhibit greater thermal sensitivity and slower temperature recovery following cold exposure, while posterior regions maintain higher and more stable temperatures. Additionally, buccal surfaces consistently show higher and more stable temperatures than lingual surfaces, underscoring the importance of measurement location for accuracy. The simulation demonstrated moderate agreement with experimental data, achieving a mean absolute error (MAE) of 3.39 °C (13.46%) for upper facial positions and 2.91 °C (10.35%) for lower facial positions during cold liquid intake scenarios. Furthermore, a strong correlation was observed between core body temperature and regional oral temperatures during prolonged cold air inhalation. While the total duration of mouth breathing significantly affects oral temperature, variations in respiratory cycle frequency showed minimal impact on thermal response. These findings provide important guidance for the development of non-invasive core temperature estimation methods based on oral biosensors. In particular, they offer insights for optimizing sensor placement in thermally stable regions and designing data-driven calibration algorithms capable of compensating for transient environmental disturbances, thereby enhancing the accuracy and reliability of wearable biosensing systems in dynamic conditions. • A computational model simulates oral temperature under various conditions. • Front teeth show slower temperature recovery and greater fluctuation. • Buccal surfaces maintain higher, more stable temperatures than lingual surfaces. • Oral cavity temperature returns to near core temperature within 15 minutes after cold exposure. • Respiratory rate has minimal impact on oral temperature during breathing.

Results in EngineeringVol. 26
University of Southern Denmark (DK), University of Oxford (GB)
UK Research and Innovation, National Institute for Health and Care Research, Department of Health and Social Care, Oxford Health NHS Foundation Trust, Directorate for Biological Sciences, Biotechnology and Biological Sciences Research Council
Openalex Percentile: Top 11%
Infrared Thermography in Medicine
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.