Peptide-based biosensor for real-time monitoring of protease biomarker activity using multi-parametric surface plasmon resonance spectroscopy

Matrix metalloproteinase-9 (MMP-9) is a key biomarker targeted in biosensing applications due to its involvement not only in maintaining good health but also in triggering various diseases such as cancer. While quantitative detection of MMP-9 is widely performed using bioanalytical detection kits such as enzyme-linked immunosorbent assay (ELISA), faster, label-free and real-time monitoring of MMP-9 activity would lead to improved disease diagnosis with better understanding of its role in underlying disease progression and development of therapeutic strategies. In this work, multi-parametric surface plasmon resonance spectroscopy (MP-SPR) is used to develop a highly sensitive MMP-9 sensor using immobilized synthetic peptides as MMP-9 substrates. Upon binding to MMP-9, the MMP-9 specific peptide is hydrolyzed between two sites of the amino acid sequence (P1 Gly and P1' Met), resulting in a decrease in the SPR signal response. The sensor detects different concentrations of MMP-9 in buffer and cell culture medium (RPMI-1640), indicating that it can be used under physiological conditions. The limit of detection (LOD) for MMP-9 in buffer is 0.34 pM and the linear detection range is between 5 pM and 9 nM, covering the clinically relevant detection range of MMP-9. To our knowledge, this is the first short synthetic peptide-based MP-SPR biosensor for monitoring MMP-9 activity. The sensor is faster than ELISA (minutes vs. hours) and provides real-time detection with access to binding kinetics information. The use of MP-SPR provides information on surface coverage and peptide thickness before and after cleavage, which is unique compared to other detection methods.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-05-15
DOI
https://doi.org/10.1016/j.bios.2025.117586
Citations
7
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
5.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peptide-based biosensor for real-time monitoring of protease biomarker activity using multi-parametric surface plasmon resonance spectroscopy

Sabrina N. Hoba, Tanja Schirmeister, Christian Kersten, Pratika Rai et al.
7 citations
Biosensors and Bioelectronics
Advanced biosensing and bioanalysis techniques
5.64
article

Peptide-based biosensor for real-time monitoring of protease biomarker activity using multi-parametric surface plasmon resonance spectroscopy

Sabrina N. Hoba, Tanja Schirmeister, Christian Kersten, Pratika Rai, Bernd Bufe, Alexey Tarasov, Celine Buchmann
article en
7 citations

Abstract

Matrix metalloproteinase-9 (MMP-9) is a key biomarker targeted in biosensing applications due to its involvement not only in maintaining good health but also in triggering various diseases such as cancer. While quantitative detection of MMP-9 is widely performed using bioanalytical detection kits such as enzyme-linked immunosorbent assay (ELISA), faster, label-free and real-time monitoring of MMP-9 activity would lead to improved disease diagnosis with better understanding of its role in underlying disease progression and development of therapeutic strategies. In this work, multi-parametric surface plasmon resonance spectroscopy (MP-SPR) is used to develop a highly sensitive MMP-9 sensor using immobilized synthetic peptides as MMP-9 substrates. Upon binding to MMP-9, the MMP-9 specific peptide is hydrolyzed between two sites of the amino acid sequence (P1 Gly and P1' Met), resulting in a decrease in the SPR signal response. The sensor detects different concentrations of MMP-9 in buffer and cell culture medium (RPMI-1640), indicating that it can be used under physiological conditions. The limit of detection (LOD) for MMP-9 in buffer is 0.34 pM and the linear detection range is between 5 pM and 9 nM, covering the clinically relevant detection range of MMP-9. To our knowledge, this is the first short synthetic peptide-based MP-SPR biosensor for monitoring MMP-9 activity. The sensor is faster than ELISA (minutes vs. hours) and provides real-time detection with access to binding kinetics information. The use of MP-SPR provides information on surface coverage and peptide thickness before and after cleavage, which is unique compared to other detection methods.

Biosensors and BioelectronicsVol. 286
Johannes Gutenberg University Mainz (DE), University of Applied Sciences Kaiserslautern (DE)
Openalex Percentile: Top 4%
Advanced biosensing and bioanalysis techniques
5.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.