Research on parallel simulation and digital twin method for temperature control of high and low temperature environment experimental chamber

Abstract High and low temperature environment experimental chamber is a key environmental testing equipment. In the actual operation of the experimental chamber, the distribution pattern and dynamic variation process of the temperature field could not be observed in real-time. To address this issue, a parallel collaborative simulation approach based on MATLAB/Simulink, Fluent, and Python was employed to construct the digital twin system for the experimental chamber. The parallel simulation and digital twin method for temperature control of the experimental chamber aims to replace physical experiments with simulations, while simultaneously enabling real-time monitoring and prediction of the experimental chamber’s operational status. The results of the simulation experiment show that the experimental chamber reaches a stable state at 909 s. The peak temperature in the simulation experiment is 80.18 °C, and the overshoot is 0.23%. The actual experimental results indicate that the experimental chamber reaches a stable state at 953 s. The peak temperature in the actual experiment is 81 °C, and the overshoot is 1.25%. Actual validation experiment results show a 1.02% difference in overshoot compared to the simulation results, and a 44 s difference in system settling time. Temperature simulation results at the measurement points inside the experimental chamber show a maximum relative error of 0.775% compared to the experimental results, demonstrating a small discrepancy between simulation and experiment. The parallel collaborative simulation and digital twin system for experimental chamber can be used to shorten the development cycle and reduce the economic costs of the experimental chamber’s research and development.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-05-15
DOI
https://doi.org/10.1088/1361-6501/add954
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on parallel simulation and digital twin method for temperature control of high and low temperature environment experimental chamber

J. Wang, Lei Jin, Hongtao Yang, Ruilin Fan
3 links
Measurement Science and Technology
Advanced Sensor and Control Systems
article

Research on parallel simulation and digital twin method for temperature control of high and low temperature environment experimental chamber

J. Wang, Lei Jin, Hongtao Yang, Ruilin Fan
article en

Abstract

Abstract High and low temperature environment experimental chamber is a key environmental testing equipment. In the actual operation of the experimental chamber, the distribution pattern and dynamic variation process of the temperature field could not be observed in real-time. To address this issue, a parallel collaborative simulation approach based on MATLAB/Simulink, Fluent, and Python was employed to construct the digital twin system for the experimental chamber. The parallel simulation and digital twin method for temperature control of the experimental chamber aims to replace physical experiments with simulations, while simultaneously enabling real-time monitoring and prediction of the experimental chamber’s operational status. The results of the simulation experiment show that the experimental chamber reaches a stable state at 909 s. The peak temperature in the simulation experiment is 80.18 °C, and the overshoot is 0.23%. The actual experimental results indicate that the experimental chamber reaches a stable state at 953 s. The peak temperature in the actual experiment is 81 °C, and the overshoot is 1.25%. Actual validation experiment results show a 1.02% difference in overshoot compared to the simulation results, and a 44 s difference in system settling time. Temperature simulation results at the measurement points inside the experimental chamber show a maximum relative error of 0.775% compared to the experimental results, demonstrating a small discrepancy between simulation and experiment. The parallel collaborative simulation and digital twin system for experimental chamber can be used to shorten the development cycle and reduce the economic costs of the experimental chamber’s research and development.

Measurement Science and TechnologyVol. 36(6)
Anhui University of Science and Technology (CN), Luxshare ICT (China) (CN)
Openalex Percentile: Top 89%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on parallel simulation and digital twin method for temperature control of high and low temperature environment experimental chamber — J. Wang, Lei Jin, et al. · Measurement Science and Technology (2025) | TGRS Research Map | TGRS