Practical Considerations of FDA’s CLAP List to Support Testing of Extractables for Pharmaceuticals and Medical Devices

The Chemical List for Analytical Performance (CLAP) was developed to support the chemical assessment of medical devices. FDA CDRH published the list, along with supporting data and with the intention that the chemicals in the list could be used to perform non-targeted extractable and simulated use extractable studies for devices. The list can be used to establish relative response factors and understand uncertainty in the context of extractable and simulated use extractable studies and can be used to demonstrate system and method suitability. This study utilizes the CLAP list to emphasize the importance of threshold identification, "semi-quantitative" assessment during the non-targeted analysis process of impurities related to Extractable and Leachable (E&L), and biocompatibility testing to ensure meaningful toxicological risk assessments. The current paper also highlights the complexity of the testing process, which involves the use of multiple analytical techniques, addresses challenges associated with screening methods, response factor databases, and the use of internal standards, and highlights a data set based on a modified CLAP list, focusing on volatiles and semivolatiles analyzed by GC-MS. The authors conclude that the CLAP list is a practical tool for establishing a basic database for GC-MS and system suitability evaluation if it has been evaluated at the AET level of the study. It has a reasonable analyte coverage at the highest studied level of 2.5 μg/mL, and the list can be used for evaluating system performance beyond direct injection of liquid extracts. Practical considerations for database generation and response factor applicability at various matrices and concentrations are discussed, with a conclusion that relative responses are generally constant at levels of 2.5 μg/mL or above and are rapidly changing at trace levels.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-05-14
DOI
https://doi.org/10.1021/acsomega.5c01982
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical Considerations of FDA’s CLAP List to Support Testing of Extractables for Pharmaceuticals and Medical Devices

Emre Seyyal, L. C. Fleck, Anna Zhachkina Michelson, Gyorgy Vas et al.
1 citations
ACS Omega
Analytical chemistry methods development
0.75
article

Practical Considerations of FDA’s CLAP List to Support Testing of Extractables for Pharmaceuticals and Medical Devices

Emre Seyyal, L. C. Fleck, Anna Zhachkina Michelson, Gyorgy Vas, Megan Flohl, Maria Tolstyakova
article en
1 citations

Abstract

The Chemical List for Analytical Performance (CLAP) was developed to support the chemical assessment of medical devices. FDA CDRH published the list, along with supporting data and with the intention that the chemicals in the list could be used to perform non-targeted extractable and simulated use extractable studies for devices. The list can be used to establish relative response factors and understand uncertainty in the context of extractable and simulated use extractable studies and can be used to demonstrate system and method suitability. This study utilizes the CLAP list to emphasize the importance of threshold identification, "semi-quantitative" assessment during the non-targeted analysis process of impurities related to Extractable and Leachable (E&L), and biocompatibility testing to ensure meaningful toxicological risk assessments. The current paper also highlights the complexity of the testing process, which involves the use of multiple analytical techniques, addresses challenges associated with screening methods, response factor databases, and the use of internal standards, and highlights a data set based on a modified CLAP list, focusing on volatiles and semivolatiles analyzed by GC-MS. The authors conclude that the CLAP list is a practical tool for establishing a basic database for GC-MS and system suitability evaluation if it has been evaluated at the AET level of the study. It has a reasonable analyte coverage at the highest studied level of 2.5 μg/mL, and the list can be used for evaluating system performance beyond direct injection of liquid extracts. Practical considerations for database generation and response factor applicability at various matrices and concentrations are discussed, with a conclusion that relative responses are generally constant at levels of 2.5 μg/mL or above and are rapidly changing at trace levels.

ACS OmegaVol. 10(20)
Intertek (Canada) (CA)
Openalex Percentile: Top 32%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Practical Considerations of FDA’s CLAP List to Support Testing of Extractables for Pharmaceuticals and Medical Devices — Emre Seyyal, L. C. Fleck, et al. · ACS Omega (2025) | TGRS Research Map | TGRS