Biomechanical performance evaluation of S2AI combine with LC-2 screw for day II pelvic crescent fracture dislocation via finite element analysis

Plate fixation is a classic method for treating day II crescent fracture dislocation of the pelvic (CFDP). However, due to the advantages of minimally invasive techniques and reduced complications associated with internal fixation percutaneous cannulated screws have emerged as a promising alternative for treating Day II CFDP. In this study, we propose using an S<sub>2</sub>AI screw combined with an LC-2 screw (S<sub>2</sub>AI + LC-2) for the treatment of Day II CFDP. The aim of this study was to compare its biomechanical stability with that of two conventional fixation methods using finite element analysis (FEA). A finite element (FE) model of pelvic was developed and validated. Three fixation methods were applied: S<sub>1</sub> sacroiliac (SI) screws combined with LC-2 screw (S<sub>1</sub> + LC-2), S<sub>1</sub> and S<sub>2</sub> SI screws combined with LC-2 screw (S<sub>1</sub> + S<sub>2</sub> + LC-2), and S<sub>2</sub>AI + LC-2. A 500 N load was applied, and the displacement of the crescent fracture fragments, the stress distribution of the implants, the displacement of the SI joint, and the maximum stress on the bone surrounding the screws were analyzed across the three FE models. After loading 500 N stress, the maximum displacement of the crescent fracture fragment and the maximum stress of bone around the implant in the S<sub>2</sub>AI + LC-2 group were the smallest in three groups. The displacement of SI joint in S<sub>2</sub>AI + LC-2 group was less than that in S<sub>1</sub> + LC-2 and S<sub>1</sub> + S<sub>2</sub> + LC-2 (P < 0.001). The maximum stress of implants in each group is smaller than the yield stress of titanium. The maximum stress of the bone around the screws at SI joint in all models lower than the yield strength of cortical bone. The maximum stress of the bone around LC-2 screws in all models lower than the yield strength of cancellous bone. The S<sub>2</sub>AI + LC-2 group can achieve reliable stability of the SI joint, and the stress on the bone around the screw could be reduced. The S<sub>2</sub>AI + LC-2 group has good biomechanical stability and can be considered as a new implant to treat Day II CFDP.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-14
DOI
https://doi.org/10.1038/s41598-025-00156-6
Citations
1
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical performance evaluation of S2AI combine with LC-2 screw for day II pelvic crescent fracture dislocation via finite element analysis

Jincheng Huang, Shenglong Qian, Ximing Liu, Zhixun Fang et al.
1 citations
Scientific Reports
Pelvic and Acetabular Injuries
2.01
article

Biomechanical performance evaluation of S2AI combine with LC-2 screw for day II pelvic crescent fracture dislocation via finite element analysis

Jincheng Huang, Shenglong Qian, Ximing Liu, Zhixun Fang, Xuan Pei, Wei Zhou, Guodong Wang, Jianyin Lei
article en
1 citations

Abstract

Plate fixation is a classic method for treating day II crescent fracture dislocation of the pelvic (CFDP). However, due to the advantages of minimally invasive techniques and reduced complications associated with internal fixation percutaneous cannulated screws have emerged as a promising alternative for treating Day II CFDP. In this study, we propose using an S<sub>2</sub>AI screw combined with an LC-2 screw (S<sub>2</sub>AI + LC-2) for the treatment of Day II CFDP. The aim of this study was to compare its biomechanical stability with that of two conventional fixation methods using finite element analysis (FEA). A finite element (FE) model of pelvic was developed and validated. Three fixation methods were applied: S<sub>1</sub> sacroiliac (SI) screws combined with LC-2 screw (S<sub>1</sub> + LC-2), S<sub>1</sub> and S<sub>2</sub> SI screws combined with LC-2 screw (S<sub>1</sub> + S<sub>2</sub> + LC-2), and S<sub>2</sub>AI + LC-2. A 500 N load was applied, and the displacement of the crescent fracture fragments, the stress distribution of the implants, the displacement of the SI joint, and the maximum stress on the bone surrounding the screws were analyzed across the three FE models. After loading 500 N stress, the maximum displacement of the crescent fracture fragment and the maximum stress of bone around the implant in the S<sub>2</sub>AI + LC-2 group were the smallest in three groups. The displacement of SI joint in S<sub>2</sub>AI + LC-2 group was less than that in S<sub>1</sub> + LC-2 and S<sub>1</sub> + S<sub>2</sub> + LC-2 (P < 0.001). The maximum stress of implants in each group is smaller than the yield stress of titanium. The maximum stress of the bone around the screws at SI joint in all models lower than the yield strength of cortical bone. The maximum stress of the bone around LC-2 screws in all models lower than the yield strength of cancellous bone. The S<sub>2</sub>AI + LC-2 group can achieve reliable stability of the SI joint, and the stress on the bone around the screw could be reduced. The S<sub>2</sub>AI + LC-2 group has good biomechanical stability and can be considered as a new implant to treat Day II CFDP.

Scientific ReportsVol. 15(1)
Central Hospital of Wuhan (CN), Wuhan General Hospital of Guangzhou (CN), Xiamen Chang Gung Hospital (CN), University Hospital Carl Gustav Carus (DE), Taiyuan University of Science and Technology (CN), Technische Universität Dresden (DE), Taiyuan University of Technology (CN)
Health Commission of Hubei Province
Openalex Percentile: Top 16%
Pelvic and Acetabular Injuries
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.