Development and validation of a method for quantitative determination of the genotoxic impurity diethyl sulfate in pitolisant hydrochloride <i>via</i> high-performance liquid chromatography

A simple and highly sensitive method was devised to detect and measure minute concentrations of diethyl sulfate (DES), a potential genotoxic impurity found in the active pharmaceutical ingredients of pitolisant hydrochloride. High-performance liquid chromatography (HPLC) was employed to accurately quantify this impurity, involving pre-column derivatization with sodium phenoxide. Chromatographic separation was achieved using a Shim-pack C18 column (250 × 4.6 mm ID × 5 μ), with a mobile phase composed of 0.01 M sodium dihydrogen orthophosphate in water (mobile phase A) and acetonitrile (mobile phase B) in a gradient elution mode at a flow rate of 1.5 mL min<sup>-1</sup> and the column temperature maintained at 25 °C. Detection was performed at 218 nm with an injection volume of 30 μL. Validation was conducted in accordance with standard International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines, encompassing parameters such as system suitability, specificity, the limit of detection (LOD), the limit of quantification (LOQ), linearity, and accuracy. The method demonstrated an LOD and LOQ of 4 ppm and 12 ppm, respectively. This developed HPLC methodology proved to be well-suited for quantifying trace levels of the potential genotoxic impurity diethyl sulfate (DES) in pitolisant hydrochloride, a by-product originating from the synthesis process.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra01217a
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a method for quantitative determination of the genotoxic impurity diethyl sulfate in pitolisant hydrochloride via high-performance liquid chromatography

Dnyaneshwar R. Shinde, Dinesh Amalnerkar, Ramdas A. Pawar, Santosh T. Shinde et al.
RSC Advances
Analytical Chemistry and Chromatography
article

Development and validation of a method for quantitative determination of the genotoxic impurity diethyl sulfate in pitolisant hydrochloride via high-performance liquid chromatography

Dnyaneshwar R. Shinde, Dinesh Amalnerkar, Ramdas A. Pawar, Santosh T. Shinde, Prakash Patil, Santosh Ramdas Bhagwat
article en

Abstract

A simple and highly sensitive method was devised to detect and measure minute concentrations of diethyl sulfate (DES), a potential genotoxic impurity found in the active pharmaceutical ingredients of pitolisant hydrochloride. High-performance liquid chromatography (HPLC) was employed to accurately quantify this impurity, involving pre-column derivatization with sodium phenoxide. Chromatographic separation was achieved using a Shim-pack C18 column (250 × 4.6 mm ID × 5 μ), with a mobile phase composed of 0.01 M sodium dihydrogen orthophosphate in water (mobile phase A) and acetonitrile (mobile phase B) in a gradient elution mode at a flow rate of 1.5 mL min<sup>-1</sup> and the column temperature maintained at 25 °C. Detection was performed at 218 nm with an injection volume of 30 μL. Validation was conducted in accordance with standard International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines, encompassing parameters such as system suitability, specificity, the limit of detection (LOD), the limit of quantification (LOQ), linearity, and accuracy. The method demonstrated an LOD and LOQ of 4 ppm and 12 ppm, respectively. This developed HPLC methodology proved to be well-suited for quantifying trace levels of the potential genotoxic impurity diethyl sulfate (DES) in pitolisant hydrochloride, a by-product originating from the synthesis process.

RSC AdvancesVol. 15(20)
Abasaheb Garware College (IN), G.S. Science, Arts And Commerce College (IN), Savitribai Phule Pune University (IN)
Good health and well-being
Openalex Percentile: Top 90%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.