Evaluation of Neutron Storage Time in Closed Chamber of the UCN Source for PIK Reactor

In 2020, a Federal Program for creating experimental facilities for the PIK reactor was started. One of the main facilities to be constructed within this Program is a new superfluid helium-based UCN source for fundamental physics research. The projected UCN density in the closed source vessel is going to be 2.1 × 103 cm–3. Work has been carried out for increasing UCN density in the source vessel by increasing neutron lifetime in superfluid helium. More than 40 m3 of isotopically pure helium-4 with a helium-3 content below 10–11 was produced to virtually eliminate the possibility of neutron absorption. Cryogenic cycle was optimised to obtain minimum helium temperature in the chamber. Work is underway to assemble the entire complex for cryogenic system testing and confirm the operating parameters of the facility.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2025-04-01
DOI
https://doi.org/10.1134/s1547477124702315
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Neutron Storage Time in Closed Chamber of the UCN Source for PIK Reactor

V. A. Lyamkin, А. П. Сиротин, A. O. Koptyuhov, D. V. Prudnikov et al.
1 citations
Physics of Particles and Nuclei Letters
Nuclear Physics and Applications
1.88
article

Evaluation of Neutron Storage Time in Closed Chamber of the UCN Source for PIK Reactor

V. A. Lyamkin, А. П. Сиротин, A. O. Koptyuhov, D. V. Prudnikov, A. П. Серебров, G. O. Borodinov, A. A. Nedolyak, P. A. Khazov
article en
1 citations

Abstract

In 2020, a Federal Program for creating experimental facilities for the PIK reactor was started. One of the main facilities to be constructed within this Program is a new superfluid helium-based UCN source for fundamental physics research. The projected UCN density in the closed source vessel is going to be 2.1 × 103 cm–3. Work has been carried out for increasing UCN density in the source vessel by increasing neutron lifetime in superfluid helium. More than 40 m3 of isotopically pure helium-4 with a helium-3 content below 10–11 was produced to virtually eliminate the possibility of neutron absorption. Cryogenic cycle was optimised to obtain minimum helium temperature in the chamber. Work is underway to assemble the entire complex for cryogenic system testing and confirm the operating parameters of the facility.

Physics of Particles and Nuclei LettersVol. 22(2)
Kurchatov Institute (RU), Petersburg Nuclear Physics Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 17%
Nuclear Physics and Applications
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Neutron Storage Time in Closed Chamber of the UCN Source for PIK Reactor — V. A. Lyamkin, А. П. Сиротин, et al. · Physics of Particles and Nuclei Letters (2025) | TGRS Research Map | TGRS