Performance and Applications of Silicon Photomultipliers for Detecting Particulate Radiations

Traditional neutron detection technologies are limited in terms of sensitivity, compactness, and response time. In such detection systems, PMTs have been the dominant option. Instead of the traditional PMTs, SiPMs offer high sensitivity, compact size, and fast response time. In the current study, SiPM principles of operation as well as its most important characteristics, such as noise rate, gain, and response time, have been investigated and discussed. Furthermore, we are proposing a technique for neutron detection based on a converter material placed on/in a scintillating medium where the induced light due to neutron interaction reads out with SiPMs. Such a technology enables the development of low-cost compact detector developments. The detector we are going to illustrate makes use of four SiPM devices, which were attached directly to the ends of a well-polished organic scintillator. This allows choosing events that are strictly coincident between the two sides of the scintillator, reducing erroneous counts. The current study revealed that in order to optimize SiPM gain (≥106), timing performance (≤100 ps), and low dark count (noise rates ≤10 μA), control of the temperature and or operating voltage is essentially important. In the current study, the best achieved time resolution was ~50 ps at 0°C and 1 V over-voltage. The study addresses the neutron detector design considerations, components, assembly method, and the preliminary detector prototype test in lap using beta particles emitted from the available strontium-90 radioactive isotope. Test results revealed that our detector prototype was able to detect and distinguish between different energy β− particles with good detection efficiency.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2025-04-01
DOI
https://doi.org/10.1134/s1547477124702285
Citations
4
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
7.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and Applications of Silicon Photomultipliers for Detecting Particulate Radiations

M.N.H. Comsan, P. Bühler, G.S.M. Ahmed, J. Márton
4 citations
Physics of Particles and Nuclei Letters
Radiation Detection and Scintillator Technologies
7.53
article

Performance and Applications of Silicon Photomultipliers for Detecting Particulate Radiations

M.N.H. Comsan, P. Bühler, G.S.M. Ahmed, J. Márton
article en
4 citations

Abstract

Traditional neutron detection technologies are limited in terms of sensitivity, compactness, and response time. In such detection systems, PMTs have been the dominant option. Instead of the traditional PMTs, SiPMs offer high sensitivity, compact size, and fast response time. In the current study, SiPM principles of operation as well as its most important characteristics, such as noise rate, gain, and response time, have been investigated and discussed. Furthermore, we are proposing a technique for neutron detection based on a converter material placed on/in a scintillating medium where the induced light due to neutron interaction reads out with SiPMs. Such a technology enables the development of low-cost compact detector developments. The detector we are going to illustrate makes use of four SiPM devices, which were attached directly to the ends of a well-polished organic scintillator. This allows choosing events that are strictly coincident between the two sides of the scintillator, reducing erroneous counts. The current study revealed that in order to optimize SiPM gain (≥106), timing performance (≤100 ps), and low dark count (noise rates ≤10 μA), control of the temperature and or operating voltage is essentially important. In the current study, the best achieved time resolution was ~50 ps at 0°C and 1 V over-voltage. The study addresses the neutron detector design considerations, components, assembly method, and the preliminary detector prototype test in lap using beta particles emitted from the available strontium-90 radioactive isotope. Test results revealed that our detector prototype was able to detect and distinguish between different energy β− particles with good detection efficiency.

Physics of Particles and Nuclei LettersVol. 22(2)
Austrian Academy of Sciences (AT), Al-Azhar University (EG), Egyptian Atomic Energy Authority (EG), Stefan Meyer Institute for Subatomic Physics (AT)
Affordable and clean energy
Openalex Percentile: Top 2%
Radiation Detection and Scintillator Technologies
7.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.