HARDWARE IN THE LOOP TESTING OF A PROTECTION MONITORING AND DIAGNOSTIC SYSTEM

Protection, automation, and control (PAC) devices are very important for the reliable operation of electric power systems (EPS), which can be improved further by monitoring the PAC devices. One way is to apply a protection monitoring and diagnostic (PMD) system, which was tested using a real-time digital simulator and two numerical protection relays in the hardware in the loop configuration. Furthermore, the communication between the protection relays and the PMD system was also tested, while the EPS faults were simulated in a safe environment on a digital simulator in real-time. When a fault occurs in the EPS, the PMD system performs the fault analysis, and generates a disturbance report within several minutes after the fault. The tested PMD system also gathers all protection relays' settings, thus reducing the workload of protection specialists significantly.

Authors

Publication Details

Journal
Journal of Energy Technology
Published
2025-04-15
DOI
https://doi.org/10.18690/jet.17.2.48-63.2024
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HARDWARE IN THE LOOP TESTING OF A PROTECTION MONITORING AND DIAGNOSTIC SYSTEM

Alexey Nebera, Boštjan Polajžer, Janez Zakonjšek, Jernej Černelič et al.
Journal of Energy Technology
Real-time simulation and control systems
article

HARDWARE IN THE LOOP TESTING OF A PROTECTION MONITORING AND DIAGNOSTIC SYSTEM

Alexey Nebera, Boštjan Polajžer, Janez Zakonjšek, Jernej Černelič, Gorazd Hrovat
article en

Abstract

Protection, automation, and control (PAC) devices are very important for the reliable operation of electric power systems (EPS), which can be improved further by monitoring the PAC devices. One way is to apply a protection monitoring and diagnostic (PMD) system, which was tested using a real-time digital simulator and two numerical protection relays in the hardware in the loop configuration. Furthermore, the communication between the protection relays and the PMD system was also tested, while the EPS faults were simulated in a safe environment on a digital simulator in real-time. When a fault occurs in the EPS, the PMD system performs the fault analysis, and generates a disturbance report within several minutes after the fault. The tested PMD system also gathers all protection relays' settings, thus reducing the workload of protection specialists significantly.

Journal of Energy TechnologyVol. 17(2)
European Commission, European Regional Development Fund
Openalex Percentile: Top 89%
Real-time simulation and control systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

HARDWARE IN THE LOOP TESTING OF A PROTECTION MONITORING AND DIAGNOSTIC SYSTEM — Alexey Nebera, Boštjan Polajžer, et al. · Journal of Energy Technology (2025) | TGRS Research Map | TGRS