EEG Baseline Analysis for Effective Extraction of P300 Event-Related Potentials for Welfare Interfaces
Enabling individuals with complete paralysis to operate devices voluntarily requires an effective interface; EEG-based P300 event-related potential (ERP) interfaces are considered a promising approach. P300 is an EEG peak generated in response to specific sensory stimuli recognized by an individual. Accurate detection of this peak necessitates a stable pre-stimulus baseline EEG signal, which serves as the reference for baseline correction. Previous studies have commonly employed either a single-time-point amplitude (e.g., at 100 ms before stimulus onset) or a time-range-averaged amplitude over a specified pre-stimulus period (e.g., 0-200 ms) as a baseline correction method, assuming these provide the most stable EEG reference. However, in assistive P300 interfaces, continuous visual stimuli at 400 ms intervals are typically used to efficiently evoke P300 peaks. Since stimuli are presented before the EEG stabilizes, it remains unclear whether conventional neuroscience baseline correction methods are suitable for such applications. To address this, the present study conducted a P300 induction experiment based on continuous 400 ms interval visual stimuli. Using EEG data recorded from 0 to 1000 ms before each visual stimulus (sampled at 1 ms intervals), we applied three baseline correction methods-single-time-point amplitude, time-range-averaged amplitude, and multi-time-point amplitude-to determine the most effective EEG reference and evaluate the impact on P300 detection performance. The results showed that baseline correction using an amplitude at a single point in time is unstable when the basic EEG rhythm and low-frequency noise remain, while time-range-averaged baseline correction using the 0-200 ms pre-stimulus period led to relatively effective P300 detection. However, it was also found that using only one value averaged over the amplitude from 0 to 200 ms did not result in an accurate EEG reference potential, resulting in an error. Finally, this study confirmed that the multi-time-point baseline correction method, through which the amplitude state from 0 to 200 ms before the visual stimulus is comprehensively evaluated, may be the most effective method for P300 determination.
Authors
- Yuta Sasatake
- Kojiro Matsushita (ORCID: https://orcid.org/0000-0002-0225-3306)
Institutions
- Gifu University (JP)
Publication Details
- Journal
- Sensors
- Published
- 2025-05-14
- DOI
- https://doi.org/10.3390/s25103102
- Citations
- 2
- Primary Topic
- EEG and Brain-Computer Interfaces
- Type
- article
- Field-Weighted Citation Impact
- 2.86