Three‐Dimensional Facial Imaging: A Comparative Assessment of the Clinical Applicability of State‐of‐the‐Art Technologies for Three‐Dimensional Facial Imaging

<b>Objective:</b> To compare the clinical applicability in terms of observer perception, patient perception, and clinical usability of stereophotogrammetry (SPG) and both static and portable structured light (SL) three-dimensional (3D) face scanners. This comparison was based on the perception of medical observers, nonmedical observers, and patients themselves, using two-dimensional (2D) photographs as clinical reference. <b>Material and Methods:</b> Facial images of 20 patients (12 females and eight males) were obtained using a professional camera (clinical reference) and three facial scanners: Vectra H1 (SPG), RAYFace RFS200 (static SL), and iReal 2E (portable SL). Instant similarity rank (ISR) and similarity score (SS) were evaluated by seven medical and six nonmedical observers, and intra- and interobserver reliability were calculated. Patients rated the overall SS (OSS) and comfort. Scanning time, processing time, need for image retake, and user-friendliness were rated by two operators who captured the images. <b>Results:</b> SPG obtained the best ISR, followed by static and portable SL. All scanners showed overall good SS and OSS. Static SL was the fastest, whereas SPG and portable SL recorded same total time. Retake rates for SPG, static SL, and portable SL were 10%, 15%, and 35%, respectively. User-friendliness and comfort ranged from moderate to good for all scanners. <b>Conclusion:</b> All tested scanners show a good clinical applicability, even though each scanner came with specific advantages and drawbacks for clinical use. SPG excelled in instant similarity, but had slower processing times. Static SL offered a balance of speed, comfort, and user-friendliness, though not always the best in similarity. Portable SL had higher retake rates and moderate comfort and user-friendliness. Similarity perception across scanners was comparable for both medical and non-medical observers, highlighting the need for clinicians to consider all scanner features to best meet clinical requirements.

Authors

Institutions

Publication Details

Journal
International Journal of Dentistry
Published
2025-01-01
DOI
https://doi.org/10.1155/ijod/8822293
Citations
4
Primary Topic
Facial Rejuvenation and Surgery Techniques
Type
article
Field-Weighted Citation Impact
8.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three‐Dimensional Facial Imaging: A Comparative Assessment of the Clinical Applicability of State‐of‐the‐Art Technologies for Three‐Dimensional Facial Imaging

Rocharles Cavalcante Fontenele, María Cadenas de Llano‐Pérula, Reinhilde Jacobs, Thanatchaporn Jindanil et al.
4 citations
International Journal of Dentistry
Facial Rejuvenation and Surgery Techniques
8.02
article

Three‐Dimensional Facial Imaging: A Comparative Assessment of the Clinical Applicability of State‐of‐the‐Art Technologies for Three‐Dimensional Facial Imaging

Rocharles Cavalcante Fontenele, María Cadenas de Llano‐Pérula, Reinhilde Jacobs, Thanatchaporn Jindanil, Lianyi Xu, Ranida Ponbuddhichai, Céline Massant
article en
4 citations

Abstract

<b>Objective:</b> To compare the clinical applicability in terms of observer perception, patient perception, and clinical usability of stereophotogrammetry (SPG) and both static and portable structured light (SL) three-dimensional (3D) face scanners. This comparison was based on the perception of medical observers, nonmedical observers, and patients themselves, using two-dimensional (2D) photographs as clinical reference. <b>Material and Methods:</b> Facial images of 20 patients (12 females and eight males) were obtained using a professional camera (clinical reference) and three facial scanners: Vectra H1 (SPG), RAYFace RFS200 (static SL), and iReal 2E (portable SL). Instant similarity rank (ISR) and similarity score (SS) were evaluated by seven medical and six nonmedical observers, and intra- and interobserver reliability were calculated. Patients rated the overall SS (OSS) and comfort. Scanning time, processing time, need for image retake, and user-friendliness were rated by two operators who captured the images. <b>Results:</b> SPG obtained the best ISR, followed by static and portable SL. All scanners showed overall good SS and OSS. Static SL was the fastest, whereas SPG and portable SL recorded same total time. Retake rates for SPG, static SL, and portable SL were 10%, 15%, and 35%, respectively. User-friendliness and comfort ranged from moderate to good for all scanners. <b>Conclusion:</b> All tested scanners show a good clinical applicability, even though each scanner came with specific advantages and drawbacks for clinical use. SPG excelled in instant similarity, but had slower processing times. Static SL offered a balance of speed, comfort, and user-friendliness, though not always the best in similarity. Portable SL had higher retake rates and moderate comfort and user-friendliness. Similarity perception across scanners was comparable for both medical and non-medical observers, highlighting the need for clinicians to consider all scanner features to best meet clinical requirements.

International Journal of DentistryVol. 2025(1)
Chulalongkorn University (TH), Universidade de São Paulo (BR), Karolinska Institutet (SE), Huazhong University of Science and Technology (CN), Catholic University of America (US), KU Leuven (BE)
Openalex Percentile: Top 3%
Facial Rejuvenation and Surgery Techniques
8.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.