Two-Stage Dynamic Partitioning Strategy Based on Grid Structure Feature and Node Voltage Characteristics for Power Systems

To enhance the adaptability of grid partitioning under transient scenarios, this paper proposes a two-stage dynamic partitioning strategy based on structure–function coupling. Electrical coupling strength is first characterized using short-circuit impedance and the sensitivity between reactive power and voltage, while transient voltage correlation is incorporated through cosine similarity as edge weights in a graph model. Grid partitioning is then conducted by maximizing modularity through a staged approach that ensures network connectivity and automatically determines partition numbers. Case studies on the modified IEEE 39-bus system demonstrate that compared with transient voltage-based partitioning and conventional complex network methods, the proposed approach improves modularity by 69%, reduces the maximum post-fault voltage deviation by 38.6%, and achieves the highest regional decoupling rate. The result shows strong intra-regional cohesion and weak inter-regional connectivity, verifying the strategy’s effectiveness in enhancing adaptability and decoupling under transient conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-14
DOI
https://doi.org/10.3390/en18102544
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Stage Dynamic Partitioning Strategy Based on Grid Structure Feature and Node Voltage Characteristics for Power Systems

Jiahao Wang, Shuo Zhang, Lixia Sun, Yiping Yu et al.
Energies
Power Systems and Technologies
article

Two-Stage Dynamic Partitioning Strategy Based on Grid Structure Feature and Node Voltage Characteristics for Power Systems

Jiahao Wang, Shuo Zhang, Lixia Sun, Yiping Yu, Xianxue Sha
article en

Abstract

To enhance the adaptability of grid partitioning under transient scenarios, this paper proposes a two-stage dynamic partitioning strategy based on structure–function coupling. Electrical coupling strength is first characterized using short-circuit impedance and the sensitivity between reactive power and voltage, while transient voltage correlation is incorporated through cosine similarity as edge weights in a graph model. Grid partitioning is then conducted by maximizing modularity through a staged approach that ensures network connectivity and automatically determines partition numbers. Case studies on the modified IEEE 39-bus system demonstrate that compared with transient voltage-based partitioning and conventional complex network methods, the proposed approach improves modularity by 69%, reduces the maximum post-fault voltage deviation by 38.6%, and achieves the highest regional decoupling rate. The result shows strong intra-regional cohesion and weak inter-regional connectivity, verifying the strategy’s effectiveness in enhancing adaptability and decoupling under transient conditions.

EnergiesVol. 18(10)
Hohai University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 91%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.