Comparison of Chromatographic and Electrochemical Methods for Detecting and Quantifying Sunscreen Agents and Their Degradation Products in Water Matrices

Comparing electroanalysis and chromatography, this study highlights that electroanalysis, specifically using a glassy carbon sensor (GCS), is the most appropriate choice for quantifying recalcitrant organic compounds. Octocrylene (OC), an organic compound commonly found in sunscreens, is of particular concern in swimming pool water monitoring, as its presence above legal limits poses health risks. OC quantification was performed using both high performance liquid chromatography (HPLC) and electroanalysis in sunscreen formulations and water matrices. The limits of detection (LODs) and quantification (LOQ) for OC were approximately 0.11 ± 0.01 mg L−1 and 0.86 ± 0.04 mg L−1 by electroanalysis, and 0.35 ± 0.02 mg L−1 and 2.86 ± 0.12 mg L−1 by HPLC. Electroanalysis successfully quantified OC in real sunscreen samples, and the results were comparable to those obtained by HPLC. The matrices tested—swimming pool water and distilled water (containing 0.002 M Cl−) contaminated with 0.4 ± 0.2 g L−1 of sunscreen (based on a maximum concentration in sunscreen and cosmetic formulations of 10%)—showed OC concentrations below 10% in the formulation, with no significant differences observed between the two techniques. GCS was further utilized to monitor OC degradation via anodic oxidation at current densities of 5 and 10 mA cm−2, using a boron-doped diamond (BDD) anode. The combined approach demonstrated high efficacy in both detecting and eliminating OC from various water matrices, making it a reliable and efficient alternative for environmental and water quality monitoring.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-05-14
DOI
https://doi.org/10.3390/app15105504
Citations
3
Primary Topic
Dye analysis and toxicity
Type
article
Field-Weighted Citation Impact
2.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Chromatographic and Electrochemical Methods for Detecting and Quantifying Sunscreen Agents and Their Degradation Products in Water Matrices

Letícia Gracyelle Alexandre Costa, Carlos Alberto Martínez-Huitle, Sergio Ferro, Elisama Vieira dos Santos et al.
3 citations
Applied Sciences
Dye analysis and toxicity
2.26
article

Comparison of Chromatographic and Electrochemical Methods for Detecting and Quantifying Sunscreen Agents and Their Degradation Products in Water Matrices

Letícia Gracyelle Alexandre Costa, Carlos Alberto Martínez-Huitle, Sergio Ferro, Elisama Vieira dos Santos, Mayra Kerolly Sales Monteiro, Laysa Renata Duarte Brito Sabino
article en
3 citations

Abstract

Comparing electroanalysis and chromatography, this study highlights that electroanalysis, specifically using a glassy carbon sensor (GCS), is the most appropriate choice for quantifying recalcitrant organic compounds. Octocrylene (OC), an organic compound commonly found in sunscreens, is of particular concern in swimming pool water monitoring, as its presence above legal limits poses health risks. OC quantification was performed using both high performance liquid chromatography (HPLC) and electroanalysis in sunscreen formulations and water matrices. The limits of detection (LODs) and quantification (LOQ) for OC were approximately 0.11 ± 0.01 mg L−1 and 0.86 ± 0.04 mg L−1 by electroanalysis, and 0.35 ± 0.02 mg L−1 and 2.86 ± 0.12 mg L−1 by HPLC. Electroanalysis successfully quantified OC in real sunscreen samples, and the results were comparable to those obtained by HPLC. The matrices tested—swimming pool water and distilled water (containing 0.002 M Cl−) contaminated with 0.4 ± 0.2 g L−1 of sunscreen (based on a maximum concentration in sunscreen and cosmetic formulations of 10%)—showed OC concentrations below 10% in the formulation, with no significant differences observed between the two techniques. GCS was further utilized to monitor OC degradation via anodic oxidation at current densities of 5 and 10 mA cm−2, using a boron-doped diamond (BDD) anode. The combined approach demonstrated high efficacy in both detecting and eliminating OC from various water matrices, making it a reliable and efficient alternative for environmental and water quality monitoring.

Applied SciencesVol. 15(10)
National Agency of Petroleum, Natural Gas and Biofuels (BR), Universidade Federal do Rio Grande do Norte (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 13%
Dye analysis and toxicity
2.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.