Background: X-ray luminescence computed tomography (XLCT) has emerged as a promising hybrid biomedical imaging modality for over a decade. However, the detector’s configuration has not been studied. Methods: We have built a benchtop XLCT imaging system and designed different detector holders to adjust the detector’s orientations and distances. Phantom experiments were performed to evaluate the performance of the detector’s configurations. We have also performed a Monte Carlo simulation to study the detectable photon numbers. Results: The photon detection efficiency is reduced by more than 10 times as the detector orientation is changed from 0 degrees to 45 degrees. The efficiency is not reduced as the detector is up to 10 mm away from the object. The efficiency is reduced by 33% when the distance is 30 mm. The numerical simulation indicates that a ring detector improves the collection efficiency by 11.3 times. Conclusions: The XLCT’s detector configuration plays a major role in the XLCT imaging system design. In the future, a ring detector will enhance the detection efficiency of XLCT imaging.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-05-14
DOI
https://doi.org/10.3390/photonics12050483
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Detector Configuration on X-Ray Luminescence Computed Tomography Imaging

Yibing Zhang, Changqing Li, Jarrod N. Cortez
Photonics
Medical Imaging Techniques and Applications
article

Effects of Detector Configuration on X-Ray Luminescence Computed Tomography Imaging

Yibing Zhang, Changqing Li, Jarrod N. Cortez
article en

Abstract

Background: X-ray luminescence computed tomography (XLCT) has emerged as a promising hybrid biomedical imaging modality for over a decade. However, the detector’s configuration has not been studied. Methods: We have built a benchtop XLCT imaging system and designed different detector holders to adjust the detector’s orientations and distances. Phantom experiments were performed to evaluate the performance of the detector’s configurations. We have also performed a Monte Carlo simulation to study the detectable photon numbers. Results: The photon detection efficiency is reduced by more than 10 times as the detector orientation is changed from 0 degrees to 45 degrees. The efficiency is not reduced as the detector is up to 10 mm away from the object. The efficiency is reduced by 33% when the distance is 30 mm. The numerical simulation indicates that a ring detector improves the collection efficiency by 11.3 times. Conclusions: The XLCT’s detector configuration plays a major role in the XLCT imaging system design. In the future, a ring detector will enhance the detection efficiency of XLCT imaging.

PhotonicsVol. 12(5)
University of California, Merced (US)
Openalex Percentile: Top 84%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.