Colorimetric Optode Sensor with Tripodal Ionophore for Rapid Urinary Ammonium Determination

The amount of ammonium excreted in urine is a crucial indicator for assessing renal metabolic acidosis. Therefore, there is a significant demand for chemical sensors capable of accurately determining urinary ammonium concentrations with high throughput. In this study, we developed an ammonia chemical sensor based on the ion-selective optode principle. This sensor employs strategically designed ionophores and a PTFE gas-permeable film to enhance selectivity for free NH<sub>3</sub>. The low basicity of the chromoionophore indicator and the weak affinity of the tripodal ammonium receptor (L, log β = 4.62 ± 0.18) contributed to a markedly reduced response time, achieving detection within seconds, a significant improvement over previous sensors. A limit of detection (LOD) of approximately 15 nM was obtained in colorimetric mode. Total inorganic ammonia content in undiluted human urine was successfully determined using the sensor. Additionally, the optode was adapted into a multiwell format, offering potential for high-throughput point-of-care testing of urinary ammonium concentrations and other samples.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-05-14
DOI
https://doi.org/10.1021/acssensors.5c00756
Citations
6
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
4.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Colorimetric Optode Sensor with Tripodal Ionophore for Rapid Urinary Ammonium Determination

Fangmei Fu, Xiaojiang Xie, Xinyu Zhang, Wei Wang
6 citations
ACS Sensors
Analytical Chemistry and Sensors
4.42
article

Colorimetric Optode Sensor with Tripodal Ionophore for Rapid Urinary Ammonium Determination

Fangmei Fu, Xiaojiang Xie, Xinyu Zhang, Wei Wang
article en
6 citations

Abstract

The amount of ammonium excreted in urine is a crucial indicator for assessing renal metabolic acidosis. Therefore, there is a significant demand for chemical sensors capable of accurately determining urinary ammonium concentrations with high throughput. In this study, we developed an ammonia chemical sensor based on the ion-selective optode principle. This sensor employs strategically designed ionophores and a PTFE gas-permeable film to enhance selectivity for free NH<sub>3</sub>. The low basicity of the chromoionophore indicator and the weak affinity of the tripodal ammonium receptor (L, log β = 4.62 ± 0.18) contributed to a markedly reduced response time, achieving detection within seconds, a significant improvement over previous sensors. A limit of detection (LOD) of approximately 15 nM was obtained in colorimetric mode. Total inorganic ammonia content in undiluted human urine was successfully determined using the sensor. Additionally, the optode was adapted into a multiwell format, offering potential for high-throughput point-of-care testing of urinary ammonium concentrations and other samples.

ACS SensorsVol. 10(5)
Hong Kong University of Science and Technology (HK), Southern University of Science and Technology (CN)
Science and Technology Foundation of Shenzhen City, National Key Research and Development Program of China
Openalex Percentile: Top 5%
Analytical Chemistry and Sensors
4.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.