A fully coupled thermal-fluid-electric-mechanics multiphysics numerical model for comprehensive performance evaluation of annular thermoelectric generators

The maximum thermal stress is an important indicator for evaluating the thermal reliability of thermoelectric generators (TEGs), but theoretical models to simultaneously predict the thermoelectric and thermomechanical performance of TEGs are lacking. Therefore, a fully coupled thermal-fluid-electric-mechanics multiphysics numerical model is established, and it is adopted to conduct a comprehensive numerical analysis of an annular TEG. Additionally, the influences of geometric parameters (height h and angle ) of thermoelectric elements and exhaust conditions on the performance of the annular TEG are studied. Numerical results reveal that reducing the thermoelectric element height ( h ) from 5 mm to 2 mm under T in = 550 K and ṁ ex = 30 g/s enhances output power by 27.6% (10.97 W to 14.02 W) but lowers conversion efficiency from 3.41% to 2.99%, while maximum thermal stress decreases by 11.6% (289.72 MPa to 256.07 MPa). Increasing the angle ( θ ) from 4° to 7° elevates output power by 11.6% (12.94 W to 14.44 W) yet reduces efficiency by 14.4% (3.34% to 2.86%), with thermal stress amplified for larger θ – θ s mismatches. Both the thermoelectric and thermomechanical performance of the annular TEG are more significantly affected by exhaust temperature compared to mass flow rate. This model integrates fluid dynamics and thermal-electric-mechanics coupling, overcoming limitations of prior studies that simplified boundary conditions. It provides actionable insights for optimizing annular TEGs in automotive waste heat recovery, balancing thermoelectric performance and thermomechanical performance.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-05-14
DOI
https://doi.org/10.1016/j.csite.2025.106329
Citations
4
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
2.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fully coupled thermal-fluid-electric-mechanics multiphysics numerical model for comprehensive performance evaluation of annular thermoelectric generators

Ding Luo, Ying Li, Zheng Li, Xuehui Wang et al.
4 citations
Case Studies in Thermal Engineering
Advanced Thermoelectric Materials and Devices
2.07
article

A fully coupled thermal-fluid-electric-mechanics multiphysics numerical model for comprehensive performance evaluation of annular thermoelectric generators

Ding Luo, Ying Li, Zheng Li, Xuehui Wang, Haokang Zhang
article en
4 citations

Abstract

The maximum thermal stress is an important indicator for evaluating the thermal reliability of thermoelectric generators (TEGs), but theoretical models to simultaneously predict the thermoelectric and thermomechanical performance of TEGs are lacking. Therefore, a fully coupled thermal-fluid-electric-mechanics multiphysics numerical model is established, and it is adopted to conduct a comprehensive numerical analysis of an annular TEG. Additionally, the influences of geometric parameters (height h and angle ) of thermoelectric elements and exhaust conditions on the performance of the annular TEG are studied. Numerical results reveal that reducing the thermoelectric element height ( h ) from 5 mm to 2 mm under T in = 550 K and ṁ ex = 30 g/s enhances output power by 27.6% (10.97 W to 14.02 W) but lowers conversion efficiency from 3.41% to 2.99%, while maximum thermal stress decreases by 11.6% (289.72 MPa to 256.07 MPa). Increasing the angle ( θ ) from 4° to 7° elevates output power by 11.6% (12.94 W to 14.44 W) yet reduces efficiency by 14.4% (3.34% to 2.86%), with thermal stress amplified for larger θ – θ s mismatches. Both the thermoelectric and thermomechanical performance of the annular TEG are more significantly affected by exhaust temperature compared to mass flow rate. This model integrates fluid dynamics and thermal-electric-mechanics coupling, overcoming limitations of prior studies that simplified boundary conditions. It provides actionable insights for optimizing annular TEGs in automotive waste heat recovery, balancing thermoelectric performance and thermomechanical performance.

Case Studies in Thermal EngineeringVol. 72
University College Dublin (IE), Chang'an University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 13%
Advanced Thermoelectric Materials and Devices
2.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.