Experimental Validation of Designs for Permeable Diffractive Lenses Based on Photon Sieves for the Sensing of Running Fluids

This study reports the experimental validation of several designs of photon sieves with focusing capabilities. These permeable optical elements were implemented with a spatial light modulator working in pure-amplitude mode. The focal region was scanned using a traveling stage, holding a camera. Using this experimental setup, we characterized the focal region of the photon sieves and determined some parameters of interest, such as the depth of focus and the transverse extent of the focal region. These parameters and their evolution were measured and analyzed to compare the optical performance of different designs. Moreover, the permeability of the mask was also evaluated and is included in the discussion. When the photon sieve is intended to be used as an optical element for the monitoring of running fluids, one of the designs studied, labeled the Ring-by-Ring method, behaves in a quite balanced manner and thus has become the preferred choice. Through simulations for a refractometric sensor, we obtained the Figure of Merit of the Ring-by-Ring mask, which reached a maximum value of 7860 RIU−1, which is competitive with plasmonic sensing devices.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-05-14
DOI
https://doi.org/10.3390/photonics12050486
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of Designs for Permeable Diffractive Lenses Based on Photon Sieves for the Sensing of Running Fluids

Ángela Soria-García, Verónica Pastor-Villarrubia, Luis Miguel Sanchez‐Brea, Mahmoud H. Elshorbagy et al.
Photonics
Analytical Chemistry and Sensors
article

Experimental Validation of Designs for Permeable Diffractive Lenses Based on Photon Sieves for the Sensing of Running Fluids

Ángela Soria-García, Verónica Pastor-Villarrubia, Luis Miguel Sanchez‐Brea, Mahmoud H. Elshorbagy, Jesús del Hoyo, Javier Alda, Joaquin Andres-Porras
article en

Abstract

This study reports the experimental validation of several designs of photon sieves with focusing capabilities. These permeable optical elements were implemented with a spatial light modulator working in pure-amplitude mode. The focal region was scanned using a traveling stage, holding a camera. Using this experimental setup, we characterized the focal region of the photon sieves and determined some parameters of interest, such as the depth of focus and the transverse extent of the focal region. These parameters and their evolution were measured and analyzed to compare the optical performance of different designs. Moreover, the permeability of the mask was also evaluated and is included in the discussion. When the photon sieve is intended to be used as an optical element for the monitoring of running fluids, one of the designs studied, labeled the Ring-by-Ring method, behaves in a quite balanced manner and thus has become the preferred choice. Through simulations for a refractometric sensor, we obtained the Figure of Merit of the Ring-by-Ring mask, which reached a maximum value of 7860 RIU−1, which is competitive with plasmonic sensing devices.

PhotonicsVol. 12(5)
Universidad Complutense de Madrid (ES), Minia University (EG)
Ministerio de Ciencia e Innovación
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.