In Vivo Cell Migration and Growth Within Electrospun Porous Nanofibrous Scaffolds with Different Pore Sizes in a Mouse Pouch Model

Cellular infiltration into traditional electrospun nanofibers (NFs) is limited due to their dense structures. We were able to obtain polycaprolactone (PCL) NFs with variable and defined pore sizes and thicknesses by using a customized programmed NF collector that controls the moving speed during electrospinning. NFs obtained by this method were tested in vitro and have shown better cell proliferation within the NFs with larger pore sizes. This study investigated in vivo host cell migration and neovascularization within implanted porous PCL NF discs using a mouse pouch model. Four types of PCL NFs were prepared and classified based on the electrospinning speed: NF-zero (static control), NF-low (0.085 mm/min), NF-mid (0.158 mm/min) and NF-high (0.232 mm/min) groups. With the increase in the speed, we observed an increase in the pore area; NF-zero (11.6 ± 6.2 μm<sup>2</sup>), NF-low (37.4 ± 28.6 μm<sup>2</sup>), NF-mid (67.6 ± 54.8 μm<sup>2</sup>), and NF-high (292.3 ± 286.5 μm<sup>2</sup>) groups. The NFs were implanted into air pouches of BALB/cJ mice. Mice without NFs served as control. Animals were sacrificed at 7 and 28 days after the implantation. Pouch tissues with implanted NFs were collected for histology (<i>n</i> = three per group and time point). The efficiency of the tissue penetration into PCL NF sheets was closely linked to the pore size and area. NFs with the highest pore area had more efficient tissue migration and new blood vessel formation compared to those with a smaller pore area. No newly formed blood vessels were observed in NF-zero sheets up to 28 days. We believe that a porous NF scaffold with a controllable pore size and thickness has great potential for tissue repair/regeneration and for other healthcare applications.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2025-05-14
DOI
https://doi.org/10.3390/jfb16050181
Citations
2
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
1.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Cell Migration and Growth Within Electrospun Porous Nanofibrous Scaffolds with Different Pore Sizes in a Mouse Pouch Model

Therese Bou‐Akl, David C. Markel, Tong Shi, Weiping Ren et al.
2 citations
Journal of Functional Biomaterials
Electrospun Nanofibers in Biomedical Applications
1.19
article

In Vivo Cell Migration and Growth Within Electrospun Porous Nanofibrous Scaffolds with Different Pore Sizes in a Mouse Pouch Model

Therese Bou‐Akl, David C. Markel, Tong Shi, Weiping Ren, Liang Chen, Xiaowei Yu, Bin Wu, Pawla Pawlitz
article en
2 citations

Abstract

Cellular infiltration into traditional electrospun nanofibers (NFs) is limited due to their dense structures. We were able to obtain polycaprolactone (PCL) NFs with variable and defined pore sizes and thicknesses by using a customized programmed NF collector that controls the moving speed during electrospinning. NFs obtained by this method were tested in vitro and have shown better cell proliferation within the NFs with larger pore sizes. This study investigated in vivo host cell migration and neovascularization within implanted porous PCL NF discs using a mouse pouch model. Four types of PCL NFs were prepared and classified based on the electrospinning speed: NF-zero (static control), NF-low (0.085 mm/min), NF-mid (0.158 mm/min) and NF-high (0.232 mm/min) groups. With the increase in the speed, we observed an increase in the pore area; NF-zero (11.6 ± 6.2 μm<sup>2</sup>), NF-low (37.4 ± 28.6 μm<sup>2</sup>), NF-mid (67.6 ± 54.8 μm<sup>2</sup>), and NF-high (292.3 ± 286.5 μm<sup>2</sup>) groups. The NFs were implanted into air pouches of BALB/cJ mice. Mice without NFs served as control. Animals were sacrificed at 7 and 28 days after the implantation. Pouch tissues with implanted NFs were collected for histology (<i>n</i> = three per group and time point). The efficiency of the tissue penetration into PCL NF sheets was closely linked to the pore size and area. NFs with the highest pore area had more efficient tissue migration and new blood vessel formation compared to those with a smaller pore area. No newly formed blood vessels were observed in NF-zero sheets up to 28 days. We believe that a porous NF scaffold with a controllable pore size and thickness has great potential for tissue repair/regeneration and for other healthcare applications.

Journal of Functional BiomaterialsVol. 16(5)
Shanghai Jiao Tong University (CN), Wayne State University (US), Providence Hospital (US), The Core Institute (US)
Life below water
Openalex Percentile: Top 23%
Electrospun Nanofibers in Biomedical Applications
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.