Fiber Balloon-Shaped SPR Sensor for Specific Detection of Cr(VI) Ions

Hexavalent chromium (Cr(VI)), as a highly toxic and carcinogenic heavy metal ion, poses a serious threat to the environment and human health. Therefore, specific detection of it is of great significance. Based on this, this article proposes a balloon shaped fiber SPR sensor with microsphere structure for specific detection of hexavalent chromium ions. The balloon structure facilitates the formation of insertable sensing probe, and the microsphere structure located on one side of the balloon structure can adjust the incidence angle of light in the sensing area to enhance the sensitivity of the sensor, resulting in a maximum refractive index sensitivity of 5068 nm/RIU. Modifying 4-mercaptoethylpyridine on the surface of the gold film of the sensor can achieve specific recognition of Cr(VI). The experimental results indicate that the balloon shaped SPR sensor with microspheres proposed in this paper has a detection limit of as low as 0.57ng/mL for Cr (VI) in the detection range of 1ng/mL-100μg/mL, with a detection time of 3 minutes, providing a new method for rapid, low concentration, and specific detection of Cr(VI).

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-14
DOI
https://doi.org/10.1109/jsen.2025.3567666
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fiber Balloon-Shaped SPR Sensor for Specific Detection of Cr(VI) Ions

Yong Wei, Chunlan Liu, Z. S. Zhang, Zhihai Liu et al.
1 citations
IEEE Sensors Journal
Analytical Chemistry and Sensors
0.74
article

Fiber Balloon-Shaped SPR Sensor for Specific Detection of Cr(VI) Ions

Yong Wei, Chunlan Liu, Z. S. Zhang, Zhihai Liu, Chao Guo, Yabin Shao, Zihao Zhao
article en
1 citations

Abstract

Hexavalent chromium (Cr(VI)), as a highly toxic and carcinogenic heavy metal ion, poses a serious threat to the environment and human health. Therefore, specific detection of it is of great significance. Based on this, this article proposes a balloon shaped fiber SPR sensor with microsphere structure for specific detection of hexavalent chromium ions. The balloon structure facilitates the formation of insertable sensing probe, and the microsphere structure located on one side of the balloon structure can adjust the incidence angle of light in the sensing area to enhance the sensitivity of the sensor, resulting in a maximum refractive index sensitivity of 5068 nm/RIU. Modifying 4-mercaptoethylpyridine on the surface of the gold film of the sensor can achieve specific recognition of Cr(VI). The experimental results indicate that the balloon shaped SPR sensor with microspheres proposed in this paper has a detection limit of as low as 0.57ng/mL for Cr (VI) in the detection range of 1ng/mL-100μg/mL, with a detection time of 3 minutes, providing a new method for rapid, low concentration, and specific detection of Cr(VI).

IEEE Sensors JournalVol. 25(13)
Harbin Engineering University (CN), Zhejiang Shuren University (CN), Chongqing Three Gorges University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 33%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.