Rapid closure and hemostasis of ruptured soft tissues using a modified human tropoelastin-based sealant in preclinical models

Treatment of injuries to soft elastic organs is often hindered by challenging anatomical features and limitations of existing sealant materials, which may lack adequate tissue adhesion, elasticity, biocompatibility, and effective hemostatic properties. To address these clinical challenges, we developed an injectable elastic sealant formulated with methacryloyl-modified human recombinant tropoelastin (MeTro) and Laponite silicate nanoplatelets (SNs). We optimized the hydrogel formulation for mechanical properties, adhesion, biocompatibility, and hemostatic properties and used visible light for cross-linking to improve safety. MeTro/SN hydrogels had increased tissue adhesion strength and burst pressure in vitro and ex vivo compared with MeTro alone or commercial sealants. The addition of SNs to the hydrogels facilitated faster blood clotting in vitro without increasing hemolysis. Applied to incisional injuries on rat lungs or aortas, MeTro/SN had burst pressures comparable to those of native tissue and greater than those of MeTro after a 7-day in vivo application. On porcine lungs, MeTro/SN also supported effective lung sealing and burst pressure similar to native lung 14 days after injury sealing. In a rodent tail hemostasis model, MeTro/SN reduced bleeding compared with MeTro. In an injured porcine lung model, early hemostasis was better than the tested commercial sealants. The results demonstrated that MeTro/SN provided effective tissue sealing and promoted hemostasis in a time frame that minimized blood loss without causing a major inflammatory response. These findings highlight the translational potential of our engineered sealant with biomimetic mechanics, durable tissue adhesion, and rapid hemostasis as a multipronged approach for the sealing and repair of traumatic injuries to soft organs.

Authors

Institutions

Publication Details

Journal
Science Translational Medicine
Published
2025-05-14
DOI
https://doi.org/10.1126/scitranslmed.adr6458
Citations
4
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
7.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid closure and hemostasis of ruptured soft tissues using a modified human tropoelastin-based sealant in preclinical models

Anthony S. Weiss, George Z. Cheng, Joshua A. Boys, Naoki Kaneko et al.
4 citations
Science Translational Medicine
Hemostasis and retained surgical items
7.08
article

Rapid closure and hemostasis of ruptured soft tissues using a modified human tropoelastin-based sealant in preclinical models

Anthony S. Weiss, George Z. Cheng, Joshua A. Boys, Naoki Kaneko, Nasim Annabi, Taichiro Imahori, Reihaneh Haghniaz, Tess De Maeseneer, Mahsa Ghovvati, Saumya Jain, Robert B. Cameron
article en
4 citations

Abstract

Treatment of injuries to soft elastic organs is often hindered by challenging anatomical features and limitations of existing sealant materials, which may lack adequate tissue adhesion, elasticity, biocompatibility, and effective hemostatic properties. To address these clinical challenges, we developed an injectable elastic sealant formulated with methacryloyl-modified human recombinant tropoelastin (MeTro) and Laponite silicate nanoplatelets (SNs). We optimized the hydrogel formulation for mechanical properties, adhesion, biocompatibility, and hemostatic properties and used visible light for cross-linking to improve safety. MeTro/SN hydrogels had increased tissue adhesion strength and burst pressure in vitro and ex vivo compared with MeTro alone or commercial sealants. The addition of SNs to the hydrogels facilitated faster blood clotting in vitro without increasing hemolysis. Applied to incisional injuries on rat lungs or aortas, MeTro/SN had burst pressures comparable to those of native tissue and greater than those of MeTro after a 7-day in vivo application. On porcine lungs, MeTro/SN also supported effective lung sealing and burst pressure similar to native lung 14 days after injury sealing. In a rodent tail hemostasis model, MeTro/SN reduced bleeding compared with MeTro. In an injured porcine lung model, early hemostasis was better than the tested commercial sealants. The results demonstrated that MeTro/SN provided effective tissue sealing and promoted hemostasis in a time frame that minimized blood loss without causing a major inflammatory response. These findings highlight the translational potential of our engineered sealant with biomimetic mechanics, durable tissue adhesion, and rapid hemostasis as a multipronged approach for the sealing and repair of traumatic injuries to soft organs.

Science Translational MedicineVol. 17(798)
West Los Angeles College (US), The University of Sydney (AU), University of California, Los Angeles (US), University of California System (US), University of California San Diego (US), Cooperative Trials Group for Neuro-Oncology (AU), Terasaki Foundation (US), VA West Los Angeles Medical Center (US)
Openalex Percentile: Top 3%
Hemostasis and retained surgical items
7.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.