Potential vision tester using Maxwellian view, small pupil, and different levels of wavefront correction with adaptive optics

We demonstrate a potential vision tester (PVT) designed to study and improve the accuracy of visual acuity (VA) measurements in the aging eye. Key features include a high-resolution visual display presented in Maxwellian view, a 3 mm pupil to limit wavefront (WF) aberrations, a Hartmann Shack wavefront sensor to quantify the ocular aberrations, and a deformable mirror to correct optical aberrations. VA was measured using four alternative forced choices for a single black-on-white E stimulus in each trial, with three different levels of correction for the ocular aberrations. For normally sighted subjects, VA was not significantly better when higher-order aberrations beyond second order were corrected.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-05-14
DOI
https://doi.org/10.1364/boe.559475
Citations
1
Primary Topic
Adaptive optics and wavefront sensing
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Potential vision tester using Maxwellian view, small pupil, and different levels of wavefront correction with adaptive optics

Ann E. Elsner, Thomas Gast, Vamsi Parimi, Stephen A. Burns
1 citations
Biomedical Optics Express
Adaptive optics and wavefront sensing
1.25
article

Potential vision tester using Maxwellian view, small pupil, and different levels of wavefront correction with adaptive optics

Ann E. Elsner, Thomas Gast, Vamsi Parimi, Stephen A. Burns
article en
1 citations

Abstract

We demonstrate a potential vision tester (PVT) designed to study and improve the accuracy of visual acuity (VA) measurements in the aging eye. Key features include a high-resolution visual display presented in Maxwellian view, a 3 mm pupil to limit wavefront (WF) aberrations, a Hartmann Shack wavefront sensor to quantify the ocular aberrations, and a deformable mirror to correct optical aberrations. VA was measured using four alternative forced choices for a single black-on-white E stimulus in each trial, with three different levels of correction for the ocular aberrations. For normally sighted subjects, VA was not significantly better when higher-order aberrations beyond second order were corrected.

Biomedical Optics ExpressVol. 16(6)
Aeon Imaging (United States) (US), Indiana University Bloomington (US)
National Eye Institute
Openalex Percentile: Top 21%
Adaptive optics and wavefront sensing
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.