Impact of Device Type and Orientation on Post-Transcatheter Aortic Valve Replacement Complications in Bicuspid Aortic Valve Patients: A Computational Study

Currently, no clinical modality reliably assists clinicians in selecting the optimal transcatheter aortic valve replacement (TAVR) device orientation. This is critical for the growing population of young bicuspid aortic valve (BAV) TAVR candidates, who are at high risk for post-procedural complications. We aim to develop a predictive computational modeling workflow to identify which TAVR device and orientation will minimize the risk of paravalvular leakage (PVL), coronary obstruction, and flow-induced thrombogenicity. We compared the risk of post-TAVR complications across more than 30 device orientation combinations by virtually implanting self-expandable and balloon-expandable TAVR devices in three BAV patients. PVL severity varied significantly with device orientation, reaching up to 22.03 mL/beat with certain self-expandable devices. For self-expandable devices, orientations that ensured the shortest distance between the taller skirt region and PVL regions minimized PVL. A shorter frame height in balloon-expandable devices was insufficient to cover PVL regions in certain patients. Pearson correlation demonstrated a negative relationship between device oversizing and PVL. The risk of flow-induced thrombogenicity was positively correlated with PVL severity. A patient-specific computational modeling workflow can identify the optimal TAVR device and orientation, minimizing life-threatening post-TAVR complications and facilitating future reinterventions for young BAV TAVR candidates.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-05-14
DOI
https://doi.org/10.1097/mat.0000000000002459
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Device Type and Orientation on Post-Transcatheter Aortic Valve Replacement Complications in Bicuspid Aortic Valve Patients: A Computational Study

Ashraf Hamdan, Rami Haj‐Ali, Puja B. Parikh, Danny Bluestein et al.
1 citations
ASAIO Journal
Cardiac Valve Diseases and Treatments
1.39
article

Impact of Device Type and Orientation on Post-Transcatheter Aortic Valve Replacement Complications in Bicuspid Aortic Valve Patients: A Computational Study

Ashraf Hamdan, Rami Haj‐Ali, Puja B. Parikh, Danny Bluestein, Salwa Anam, Marvin J. Slepian, Brandon Kovarovic
article en
1 citations

Abstract

Currently, no clinical modality reliably assists clinicians in selecting the optimal transcatheter aortic valve replacement (TAVR) device orientation. This is critical for the growing population of young bicuspid aortic valve (BAV) TAVR candidates, who are at high risk for post-procedural complications. We aim to develop a predictive computational modeling workflow to identify which TAVR device and orientation will minimize the risk of paravalvular leakage (PVL), coronary obstruction, and flow-induced thrombogenicity. We compared the risk of post-TAVR complications across more than 30 device orientation combinations by virtually implanting self-expandable and balloon-expandable TAVR devices in three BAV patients. PVL severity varied significantly with device orientation, reaching up to 22.03 mL/beat with certain self-expandable devices. For self-expandable devices, orientations that ensured the shortest distance between the taller skirt region and PVL regions minimized PVL. A shorter frame height in balloon-expandable devices was insufficient to cover PVL regions in certain patients. Pearson correlation demonstrated a negative relationship between device oversizing and PVL. The risk of flow-induced thrombogenicity was positively correlated with PVL severity. A patient-specific computational modeling workflow can identify the optimal TAVR device and orientation, minimizing life-threatening post-TAVR complications and facilitating future reinterventions for young BAV TAVR candidates.

ASAIO JournalVol. 72(1)
University of Arizona (US), Tel Aviv University (IL), Rabin Medical Center (IL), Stony Brook School (US), Stony Brook University (US)
Openalex Percentile: Top 19%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.