Calculation of quality factors for space radiation at low Earth orbit: Monte Carlo-based microdosimetric approach

This study aims to calculate quality factors (<i>Q</i>) for the radiation environment at low Earth orbit using Monte Carlo-based microdosimetric techniques. This study considers Galactic Cosmic Ray (GCR) ions (<i>Z</i>= 1-28), trapped protons, and albedo neutrons.<i>Q</i>is calculated with (2.8 g cm<sup>-2</sup>polyethylene and 10 g cm<sup>-2</sup>thick aluminum) and without shielding. FLUKA code is used to model a uniform radiation environment incident on a spherical spacecraft having the above shielding material while a spherical tissue-equivalent proportional counter (TEPC) is positioned at the center of this spherical envelope. The initial fluence spectra of the above radiation fields are based on the OLTARIS code. Microdosimetric distributions in the cavity of the TEPC are calculated separately for GCR ions, trapped protons, and albedo neutrons. Using the microdosimetric distributions,<i>Q</i>values for these radiations including mission<i>Q</i>values are calculated based on the theory of dual radiation action (TDRA) model, and the formalisms based on ICRP60 and ICRU40.<i>Q</i>initially increases with the<i>Z</i>of the ion, but beyond<i>Z</i>= 22, it becomes insensitive to<i>Z</i>. Depending on the calculation model, the mission<i>Q</i>value is in the range of 1.91-2.45 for no shielding, 1.67-2.07 for 2.8 g cm<sup>-2</sup>polyethylene shielding, and 1.81-2.48 for 10 g cm<sup>-2</sup>aluminum shielding. The microdosimetry-based mission<i>Q</i>values corresponding to 2.8 g cm<sup>-2</sup>polyethylene shielding calculated according to the ICRP60 and ICRU40 models compare well with the published measured values of previous space missions. The calculated TDRA-based<i>Q</i>values compare well with the values derived from the OLTARIS code. A significant reduction in the dose equivalent is achieved with 10 g cm<sup>-2</sup>Al shielding as compared to 2.8 g cm<sup>-2</sup>polyethylene. Overall, the study enhances the understanding of how shielding influences<i>Q</i>and dose equivalent.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2025-05-14
DOI
https://doi.org/10.1088/1361-6498/add89c
Citations
2
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation of quality factors for space radiation at low Earth orbit: Monte Carlo-based microdosimetric approach

T. Palani Selvam, Balvinder Kaur Sapra, R. S. Vishwakarma, Arghya Chattaraj
2 citations
Journal of Radiological Protection
Radiation Therapy and Dosimetry
3.04
article

Calculation of quality factors for space radiation at low Earth orbit: Monte Carlo-based microdosimetric approach

T. Palani Selvam, Balvinder Kaur Sapra, R. S. Vishwakarma, Arghya Chattaraj
article en
2 citations

Abstract

This study aims to calculate quality factors (<i>Q</i>) for the radiation environment at low Earth orbit using Monte Carlo-based microdosimetric techniques. This study considers Galactic Cosmic Ray (GCR) ions (<i>Z</i>= 1-28), trapped protons, and albedo neutrons.<i>Q</i>is calculated with (2.8 g cm<sup>-2</sup>polyethylene and 10 g cm<sup>-2</sup>thick aluminum) and without shielding. FLUKA code is used to model a uniform radiation environment incident on a spherical spacecraft having the above shielding material while a spherical tissue-equivalent proportional counter (TEPC) is positioned at the center of this spherical envelope. The initial fluence spectra of the above radiation fields are based on the OLTARIS code. Microdosimetric distributions in the cavity of the TEPC are calculated separately for GCR ions, trapped protons, and albedo neutrons. Using the microdosimetric distributions,<i>Q</i>values for these radiations including mission<i>Q</i>values are calculated based on the theory of dual radiation action (TDRA) model, and the formalisms based on ICRP60 and ICRU40.<i>Q</i>initially increases with the<i>Z</i>of the ion, but beyond<i>Z</i>= 22, it becomes insensitive to<i>Z</i>. Depending on the calculation model, the mission<i>Q</i>value is in the range of 1.91-2.45 for no shielding, 1.67-2.07 for 2.8 g cm<sup>-2</sup>polyethylene shielding, and 1.81-2.48 for 10 g cm<sup>-2</sup>aluminum shielding. The microdosimetry-based mission<i>Q</i>values corresponding to 2.8 g cm<sup>-2</sup>polyethylene shielding calculated according to the ICRP60 and ICRU40 models compare well with the published measured values of previous space missions. The calculated TDRA-based<i>Q</i>values compare well with the values derived from the OLTARIS code. A significant reduction in the dose equivalent is achieved with 10 g cm<sup>-2</sup>Al shielding as compared to 2.8 g cm<sup>-2</sup>polyethylene. Overall, the study enhances the understanding of how shielding influences<i>Q</i>and dose equivalent.

Journal of Radiological ProtectionVol. 45(2)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN), Bhabha Atomic Research Center Hospital (IN)
Openalex Percentile: Top 10%
Radiation Therapy and Dosimetry
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.