Whole-body CT-to-PET synthesis using a customized transformer-enhanced GAN

<i>Background</i>. Positron emission tomography with 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography (18F-FDG PET-CT) is a multi-modality medical imaging technique widely used for screening and diagnosis of lesions and tumors, in which, CT can provide detailed anatomical structures, while PET can show metabolic activities. Nevertheless, it has disadvantages such as long scanning time, high cost, and relatively high radiation doses.<i>Purpose</i>. We propose a deep learning model for the whole-body CT-to-PET synthesis task, generating high-quality synthetic PET images that are comparable to real ones in both clinical relevance and diagnostic value.<i>Material</i>. We collect 102 pairs of 3D CT and PET scans, which are sliced into 27 240 pairs of 2D CT and PET images (training: 21,855 pairs, validation: 2810 pairs, testing: 2575 pairs).<i>Methods</i>. We propose a transformer-enhanced generative adversarial network (GAN) for whole-body CT-to-PET synthesis task. The CPGAN model uses residual blocks and fully connected transformer residual blocks to capture both local features and global contextual information. A customized loss function incorporating structural consistency is designed to improve the quality of synthesized PET images.<i>Results</i>. Both quantitative and qualitative evaluation results demonstrate effectiveness of the CPGAN model. The mean and standard variance of NRMSE, PSNR and SSIM values on test set are(16.90±12.27)×10-4,28.71±2.67and0.926±0.033, respectively, outperforming other seven state-of-the-art models. Three radiologists independently and blindly evaluated and gave subjective scores to 100 randomly chosen PET images (50 real and 50 synthetic). By Wilcoxon signed rank test, there are no statistical differences between the synthetic PET images and the real ones.<i>Conclusions</i>. Despite the inherent limitations of CT images to directly reflect biological information of metabolic tissues, CPGAN model effectively synthesizes satisfying PET images from CT scans, which has potential in reducing the reliance on actual PET-CT scans.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-05-14
DOI
https://doi.org/10.1088/1361-6560/add8dd
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Whole-body CT-to-PET synthesis using a customized transformer-enhanced GAN

Ziwei Nie, Aimei Li, Bo Xu, Jian He et al.
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

Whole-body CT-to-PET synthesis using a customized transformer-enhanced GAN

Ziwei Nie, Aimei Li, Bo Xu, Jian He, Ting Wu
article en

Abstract

<i>Background</i>. Positron emission tomography with 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography (18F-FDG PET-CT) is a multi-modality medical imaging technique widely used for screening and diagnosis of lesions and tumors, in which, CT can provide detailed anatomical structures, while PET can show metabolic activities. Nevertheless, it has disadvantages such as long scanning time, high cost, and relatively high radiation doses.<i>Purpose</i>. We propose a deep learning model for the whole-body CT-to-PET synthesis task, generating high-quality synthetic PET images that are comparable to real ones in both clinical relevance and diagnostic value.<i>Material</i>. We collect 102 pairs of 3D CT and PET scans, which are sliced into 27 240 pairs of 2D CT and PET images (training: 21,855 pairs, validation: 2810 pairs, testing: 2575 pairs).<i>Methods</i>. We propose a transformer-enhanced generative adversarial network (GAN) for whole-body CT-to-PET synthesis task. The CPGAN model uses residual blocks and fully connected transformer residual blocks to capture both local features and global contextual information. A customized loss function incorporating structural consistency is designed to improve the quality of synthesized PET images.<i>Results</i>. Both quantitative and qualitative evaluation results demonstrate effectiveness of the CPGAN model. The mean and standard variance of NRMSE, PSNR and SSIM values on test set are(16.90±12.27)×10-4,28.71±2.67and0.926±0.033, respectively, outperforming other seven state-of-the-art models. Three radiologists independently and blindly evaluated and gave subjective scores to 100 randomly chosen PET images (50 real and 50 synthetic). By Wilcoxon signed rank test, there are no statistical differences between the synthetic PET images and the real ones.<i>Conclusions</i>. Despite the inherent limitations of CT images to directly reflect biological information of metabolic tissues, CPGAN model effectively synthesizes satisfying PET images from CT scans, which has potential in reducing the reliance on actual PET-CT scans.

Physics in Medicine and BiologyVol. 70(11)
Hankou University (CN), Nanjing University of Science and Technology (CN), Nanjing Drum Tower Hospital (CN), Nanjing University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, National Science and Technology Major Project
Openalex Percentile: Top 84%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.