Application of electrospun membranes of polylactic acid and polypyrrole as a biosensor for the detection of cholesterol

<b>Background:</b> Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) plays a crucial role in various industries and enzymatic reactions, including cholesterol oxidation. Cholesterol, vital for physiological functions, can lead to cardiovascular and hepatic diseases when present in excess. Accurate detection is crucial, yet current techniques are costly and time-consuming. Biosensors offer a promising alternative due to their sensitivity, speed, and portability in detecting H<sub>2</sub>O<sub>2</sub>. <b>Objective:</b> This study aims to develop a sensitive, simple, rapid, and cost-effective biosensor for H<sub>2</sub>O<sub>2</sub> detection using electrospun membranes coated with polypyrrole (PPy). <b>Methods:</b> Poly(lactic acid) (PLA) membranes were prepared using the electrospinning technique. Subsequently, these membranes were coated with polypyrrole (PPy) through in situ chemical polymerization. The obtained materials were characterized using SEM, contact angle measurements, XPS, and their electrical properties were analyzed. <b>Results</b>: PLA/PPy composite membranes exhibited electrical conductivities on the order of 10<sup>-2</sup> S cm<sup>-1</sup>. Upon exposure to H<sub>2</sub>O<sub>2</sub> and enzymatic reaction, a significant decrease in their electrical properties was observed, indicating their potential as sensors for detecting this analyte. <b>Conclusions:</b> Electrospun PLA/PPy membranes demonstrate high potential for H<sub>2</sub>O<sub>2</sub> detection, owing to their large surface area and high reactivity, thereby enhancing sensor sensitivity. These characteristics make this material a promising option for H<sub>2</sub>O<sub>2</sub> detection applications across various industries.

Authors

Institutions

Publication Details

Journal
Bio-Medical Materials and Engineering
Published
2025-05-14
DOI
https://doi.org/10.1177/09592989251341131
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of electrospun membranes of polylactic acid and polypyrrole as a biosensor for the detection of cholesterol

Damián F. Plascencia-Martínez, R. Ramı́rez-Bon, G. Suárez-Campos, David Andrés Fernández-Benavides et al.
1 citations
Bio-Medical Materials and Engineering
Electrochemical sensors and biosensors
0.73
article

Application of electrospun membranes of polylactic acid and polypyrrole as a biosensor for the detection of cholesterol

Damián F. Plascencia-Martínez, R. Ramı́rez-Bon, G. Suárez-Campos, David Andrés Fernández-Benavides, Jesús Manuel Quiroz‐Castillo, Lorena Armenta‐Villegas, Ángel Ulises Orozco-Valencia, M.M. Castillo-Ortega, D.E. Rodríguez-Félix, Ana Daymi Cabrera-González, Claudia Georgina Ramirez-Mendoza, José Ramón Flores‐León
article en
1 citations

Abstract

<b>Background:</b> Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) plays a crucial role in various industries and enzymatic reactions, including cholesterol oxidation. Cholesterol, vital for physiological functions, can lead to cardiovascular and hepatic diseases when present in excess. Accurate detection is crucial, yet current techniques are costly and time-consuming. Biosensors offer a promising alternative due to their sensitivity, speed, and portability in detecting H<sub>2</sub>O<sub>2</sub>. <b>Objective:</b> This study aims to develop a sensitive, simple, rapid, and cost-effective biosensor for H<sub>2</sub>O<sub>2</sub> detection using electrospun membranes coated with polypyrrole (PPy). <b>Methods:</b> Poly(lactic acid) (PLA) membranes were prepared using the electrospinning technique. Subsequently, these membranes were coated with polypyrrole (PPy) through in situ chemical polymerization. The obtained materials were characterized using SEM, contact angle measurements, XPS, and their electrical properties were analyzed. <b>Results</b>: PLA/PPy composite membranes exhibited electrical conductivities on the order of 10<sup>-2</sup> S cm<sup>-1</sup>. Upon exposure to H<sub>2</sub>O<sub>2</sub> and enzymatic reaction, a significant decrease in their electrical properties was observed, indicating their potential as sensors for detecting this analyte. <b>Conclusions:</b> Electrospun PLA/PPy membranes demonstrate high potential for H<sub>2</sub>O<sub>2</sub> detection, owing to their large surface area and high reactivity, thereby enhancing sensor sensitivity. These characteristics make this material a promising option for H<sub>2</sub>O<sub>2</sub> detection applications across various industries.

Bio-Medical Materials and EngineeringVol. 36(5)
Universidad de Sonora (MX), Center for Engineering and Industrial Development (MX), Instituto Politécnico Nacional (MX)
Openalex Percentile: Top 28%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.