Automation and control of an experimental protonic membrane steam methane reforming system

Nickel dispersion on doped barium-zirconate ceramics is a state-of-the-art material formulation used to fabricate proton conducting membranes that can reform methane at lower operational temperatures (600 to 800 ° C ). Although steady-state operational data have been reported for these ion-conducting ceramic reformers, transient datasets are uncommon and not readily available. Moreover, the automation of protonic membrane reformers is a major technical challenge for the commercialization of modular thermo-electrochemical hydrogen generators with highly nonlinear process dynamics. Here, a multi-input multi-output feedback control scheme has been designed from a relative gain array analysis of three process variables for an experimental 500 W (thermal and electrochemical power consumption) protonic membrane reforming system. Specifically, the proposed control architecture automatically calculates hydrogen separation rate setpoints while safely and effectively reaching hydrogen production rate setpoints and desired steam-to-carbon ratios. The control architecture also drives the system to 99.6% methane conversion at a current density of 0.564 ± 0.0125 A ⋅ cm −2 at 788 ° C . Internal temperature fluctuations are mostly constrained to ± 6.00 ° C ⋅ min −1 , which improves catalyst longevity when operating at hydrogen recovery rates exceeding 50%. Chief among these findings is an experimental demonstration of a control scenario that alters the hydrogen production rate setpoint every 150 min without sacrificing system-wide controllability. Integrator windup scenarios and counterproductive control actions are also avoided through rational controller design and proper controller tuning exercises. Industrial-scale applications of protonic membrane reformers may therefore be automated to control up to three process variables and have up to three additional control degrees of freedom for process intensification and optimization, making for well-governed, autonomous hydrogen generation units.

Authors

Institutions

Publication Details

Journal
Digital Chemical Engineering
Published
2025-05-14
DOI
https://doi.org/10.1016/j.dche.2025.100240
Citations
1
Primary Topic
Catalysts for Methane Reforming
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automation and control of an experimental protonic membrane steam methane reforming system

Christopher Donahue, Panagiotis D. Christofides, Dominic Peters, Carlos G. Morales‐Guio et al.
1 citations
Digital Chemical Engineering
Catalysts for Methane Reforming
0.39
article

Automation and control of an experimental protonic membrane steam methane reforming system

Christopher Donahue, Panagiotis D. Christofides, Dominic Peters, Carlos G. Morales‐Guio, Yifei Wang, Xiaodong Cui, J. Steven Stanley
article en
1 citations

Abstract

Nickel dispersion on doped barium-zirconate ceramics is a state-of-the-art material formulation used to fabricate proton conducting membranes that can reform methane at lower operational temperatures (600 to 800 ° C ). Although steady-state operational data have been reported for these ion-conducting ceramic reformers, transient datasets are uncommon and not readily available. Moreover, the automation of protonic membrane reformers is a major technical challenge for the commercialization of modular thermo-electrochemical hydrogen generators with highly nonlinear process dynamics. Here, a multi-input multi-output feedback control scheme has been designed from a relative gain array analysis of three process variables for an experimental 500 W (thermal and electrochemical power consumption) protonic membrane reforming system. Specifically, the proposed control architecture automatically calculates hydrogen separation rate setpoints while safely and effectively reaching hydrogen production rate setpoints and desired steam-to-carbon ratios. The control architecture also drives the system to 99.6% methane conversion at a current density of 0.564 ± 0.0125 A ⋅ cm −2 at 788 ° C . Internal temperature fluctuations are mostly constrained to ± 6.00 ° C ⋅ min −1 , which improves catalyst longevity when operating at hydrogen recovery rates exceeding 50%. Chief among these findings is an experimental demonstration of a control scenario that alters the hydrogen production rate setpoint every 150 min without sacrificing system-wide controllability. Integrator windup scenarios and counterproductive control actions are also avoided through rational controller design and proper controller tuning exercises. Industrial-scale applications of protonic membrane reformers may therefore be automated to control up to three process variables and have up to three additional control degrees of freedom for process intensification and optimization, making for well-governed, autonomous hydrogen generation units.

Digital Chemical EngineeringVol. 15
University of California, Los Angeles (US)
Openalex Percentile: Top 45%
Catalysts for Methane Reforming
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.