Real-World Evidence on Lead Extraction Following Cardiac Implantable Electronic Device (CIED) Infections and Its Association With 1-year Mortality

Complete lead extraction is strongly recommended for managing cardiac implantable electronic device (CIED) infections. However, actual practices and associated patient outcomes in real-world settings are not well documented. This study aims to quantify use of lead extraction among Australian patients with CIED infections. In this retrospective cohort study, we analyzed linked hospital and mortality data from New South Wales (July 2008 to September 2022). We included patients aged ≥18 years diagnosed with CIED infections, identified using diagnosis codes T82.71 (from July 2017 onwards) and T82.7 with relevant supplementary codes prior to July 2017. We quantified the association between lead extraction and 1-year mortality using time-varying Cox proportional hazards regression models. We included 2,339 patients (mean age 72.5 years, 31.5% female) who were hospitalized with CIED infections, of which 24.0% (n = 561) underwent lead extraction within 30 days. The likelihood of lead extraction was higher among those with sepsis, endocarditis, Staphylococcus aureus infection, prior revision/replacement CIED procedures, and patients admitted to private hospitals. In contrast, older patients (aged 75+ years), female patients, and those with chronic kidney disease were less likely to undergo lead extraction. Lead extraction was associated with reduced 1-year mortality rate (adjusted-HR = 0.64, 95% CI: 0.51 to 0.81), with evidence of greater survival benefit in patients with sepsis and lesser benefit in older patients and females. In conclusion, utilization of lead extraction was limited among patients with CIED infections. Lead extraction was linked to significantly reduced mortality rate, highlighting the importance of improving adherence to recommended management for patients with CIED infections.

Authors

Institutions

Publication Details

Journal
The American Journal of Cardiology
Published
2025-05-14
DOI
https://doi.org/10.1016/j.amjcard.2025.05.015
Citations
3
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
4.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-World Evidence on Lead Extraction Following Cardiac Implantable Electronic Device (CIED) Infections and Its Association With 1-year Mortality

Jennifer Yu, Sze‐Yuan Ooi, Md Shajedur Rahman Shawon, Louisa Jorm et al.
3 citations
The American Journal of Cardiology
Cardiac pacing and defibrillation studies
4.16
article

Real-World Evidence on Lead Extraction Following Cardiac Implantable Electronic Device (CIED) Infections and Its Association With 1-year Mortality

Jennifer Yu, Sze‐Yuan Ooi, Md Shajedur Rahman Shawon, Louisa Jorm, Sean Gomes
article en
3 citations

Abstract

Complete lead extraction is strongly recommended for managing cardiac implantable electronic device (CIED) infections. However, actual practices and associated patient outcomes in real-world settings are not well documented. This study aims to quantify use of lead extraction among Australian patients with CIED infections. In this retrospective cohort study, we analyzed linked hospital and mortality data from New South Wales (July 2008 to September 2022). We included patients aged ≥18 years diagnosed with CIED infections, identified using diagnosis codes T82.71 (from July 2017 onwards) and T82.7 with relevant supplementary codes prior to July 2017. We quantified the association between lead extraction and 1-year mortality using time-varying Cox proportional hazards regression models. We included 2,339 patients (mean age 72.5 years, 31.5% female) who were hospitalized with CIED infections, of which 24.0% (n = 561) underwent lead extraction within 30 days. The likelihood of lead extraction was higher among those with sepsis, endocarditis, Staphylococcus aureus infection, prior revision/replacement CIED procedures, and patients admitted to private hospitals. In contrast, older patients (aged 75+ years), female patients, and those with chronic kidney disease were less likely to undergo lead extraction. Lead extraction was associated with reduced 1-year mortality rate (adjusted-HR = 0.64, 95% CI: 0.51 to 0.81), with evidence of greater survival benefit in patients with sepsis and lesser benefit in older patients and females. In conclusion, utilization of lead extraction was limited among patients with CIED infections. Lead extraction was linked to significantly reduced mortality rate, highlighting the importance of improving adherence to recommended management for patients with CIED infections.

The American Journal of CardiologyVol. 251
UNSW Sydney (AU), Prince of Wales Hospital (AU)
National Health and Medical Research Council
Good health and well-being
Openalex Percentile: Top 6%
Cardiac pacing and defibrillation studies
4.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.