Improving Diagnostic Safety by minimizing errors in Preanalytical Phase of Laboratory Testing Process

The role of laboratory medicine is indispensable for the healthcare industry. Laboratory Services is a rapidly expanding field which contributes significantly 60–70% of clinical decisions regarding hospitalization, discharge, and medications of patients. Total laboratory testing is a cyclical process which is divided into three phases: preanalytical, analytical and postanalytical phase. The pre-analytical phase is a complex process and performed outside the laboratory. Available evidence demonstrates that the most common errors occur in the pre-analytical phase (46–68.2% of total errors). User’s feedback was collected proactively to find the gaps in the exiting process. Retrospective data was collected from February to July 2023, and it was evident that average sample rejection rate was significantly higher 2.56%, wrong investigation order error was 1.65% and sample transportation time was prolonged (average 160 minutes for inpatient and 79 min for outpatient department) in Evercare hospital Dhaka. Therefore, Laboratory stakeholders and senior leaders of Evercare hospital Dhaka decided to start hospital wide quality improvement project. The objective of this study is to identify the gaps in the preanalytical phase of diagnostic services. It was aimed to minimize the errors by developing and implementing effective quality initiatives and was targeted to decrease sample rejection rate below 2%, reduce wrong investigation input rate below 1% and to maintain IPD sample transportation TAT within 120 minutes and OPD sample transportation TAT within 60 minutes. After implementing multiple effective quality initiatives EHD successfully achieved the target and reduced sample rejection rate 1.5%, reduced investigation order error rate 0.8% and maintained sample transportation TAT for IPD 119.9 minutes and for OPD 59.2 minutes. Pulse Volume 16, Issue 2 2024, P: 19-26

Authors

Institutions

Publication Details

Journal
Pulse
Published
2025-05-14
DOI
https://doi.org/10.3329/pulse.v16i2.81675
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Diagnostic Safety by minimizing errors in Preanalytical Phase of Laboratory Testing Process

Tahmina Rahman, Rezina Ahmed, Debashish Saha
Pulse
Fault Detection and Control Systems
article

Improving Diagnostic Safety by minimizing errors in Preanalytical Phase of Laboratory Testing Process

Tahmina Rahman, Rezina Ahmed, Debashish Saha
article en

Abstract

The role of laboratory medicine is indispensable for the healthcare industry. Laboratory Services is a rapidly expanding field which contributes significantly 60–70% of clinical decisions regarding hospitalization, discharge, and medications of patients. Total laboratory testing is a cyclical process which is divided into three phases: preanalytical, analytical and postanalytical phase. The pre-analytical phase is a complex process and performed outside the laboratory. Available evidence demonstrates that the most common errors occur in the pre-analytical phase (46–68.2% of total errors). User’s feedback was collected proactively to find the gaps in the exiting process. Retrospective data was collected from February to July 2023, and it was evident that average sample rejection rate was significantly higher 2.56%, wrong investigation order error was 1.65% and sample transportation time was prolonged (average 160 minutes for inpatient and 79 min for outpatient department) in Evercare hospital Dhaka. Therefore, Laboratory stakeholders and senior leaders of Evercare hospital Dhaka decided to start hospital wide quality improvement project. The objective of this study is to identify the gaps in the preanalytical phase of diagnostic services. It was aimed to minimize the errors by developing and implementing effective quality initiatives and was targeted to decrease sample rejection rate below 2%, reduce wrong investigation input rate below 1% and to maintain IPD sample transportation TAT within 120 minutes and OPD sample transportation TAT within 60 minutes. After implementing multiple effective quality initiatives EHD successfully achieved the target and reduced sample rejection rate 1.5%, reduced investigation order error rate 0.8% and maintained sample transportation TAT for IPD 119.9 minutes and for OPD 59.2 minutes. Pulse Volume 16, Issue 2 2024, P: 19-26

PulseVol. 16(2)
National Committee for Quality Assurance (US), Square Hospitals (BD)
Openalex Percentile: Top 89%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.