Trans- catheter Closure of Large Tubular PDA Followed by Post Device Closure Syndrome: A case study

Patent ductus arteriosus (PDA) is the commonest congenital heart disease. PDA can be closed by trans-catheter device implantation or surgical closure. Pediatric cardiologists have been closing the PDA with device with tremendous success. Although large PDA device closure followed by post device closure syndrome is rare, this clinical condition can be managed by pre device implantation evaluation of predictor factors. Our patient had large tubular PDA which was properly evaluated before ADO I device implantation and managed his post device closure syndrome evidenced by left ventricular dysfunction and sudden rise of systemic blood pressure. His post device closure syndrome and para device leak were properly managed during hospital stay and close follow up. Pulse Volume 16, Issue 2 2024, P: 35-38

Authors

Institutions

Publication Details

Journal
Pulse
Published
2025-05-14
DOI
https://doi.org/10.3329/pulse.v16i2.81685
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trans- catheter Closure of Large Tubular PDA Followed by Post Device Closure Syndrome: A case study

Tahera Nazrin
Pulse
Central Venous Catheters and Hemodialysis
article

Trans- catheter Closure of Large Tubular PDA Followed by Post Device Closure Syndrome: A case study

Tahera Nazrin
article en

Abstract

Patent ductus arteriosus (PDA) is the commonest congenital heart disease. PDA can be closed by trans-catheter device implantation or surgical closure. Pediatric cardiologists have been closing the PDA with device with tremendous success. Although large PDA device closure followed by post device closure syndrome is rare, this clinical condition can be managed by pre device implantation evaluation of predictor factors. Our patient had large tubular PDA which was properly evaluated before ADO I device implantation and managed his post device closure syndrome evidenced by left ventricular dysfunction and sudden rise of systemic blood pressure. His post device closure syndrome and para device leak were properly managed during hospital stay and close follow up. Pulse Volume 16, Issue 2 2024, P: 35-38

PulseVol. 16(2)
Square Hospitals (BD)
Openalex Percentile: Top 83%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.