Analysis and Design of LLC Resonant High-Voltage Converters with Magnetic Integration

In the lab, a high-frequency high-voltage transformer's impedance and frequency characteristics are measured using an impedance analyzer. the parasitic parameters are extracted to design the LLC resonant converter's resonant frequency, operating frequency range, and select suitable components to meet the design requirements. The impact of parasitic parameters on the LLC resonant converter is analyzed, and optimization methods are proposed. The calculated results meet the design requirements and are verified through simulation and experimentation. The designed magnetic integration LLC resonant high-voltage converter's output voltage is stable at around 2kV, and the simulation results match the experimental results, verifying the feasibility of this method.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1145/3717934.3717996
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Design of LLC Resonant High-Voltage Converters with Magnetic Integration

Bingqian Wang, Dawei Zhang
Induction Heating and Inverter Technology
article

Analysis and Design of LLC Resonant High-Voltage Converters with Magnetic Integration

Bingqian Wang, Dawei Zhang
article en

Abstract

In the lab, a high-frequency high-voltage transformer's impedance and frequency characteristics are measured using an impedance analyzer. the parasitic parameters are extracted to design the LLC resonant converter's resonant frequency, operating frequency range, and select suitable components to meet the design requirements. The impact of parasitic parameters on the LLC resonant converter is analyzed, and optimization methods are proposed. The calculated results meet the design requirements and are verified through simulation and experimentation. The designed magnetic integration LLC resonant high-voltage converter's output voltage is stable at around 2kV, and the simulation results match the experimental results, verifying the feasibility of this method.

Shenyang University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 71%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.