Grid Connected Hybrid System Power Quality Examination

This study investigates the oversight technique & simulation of a combination system which includes (SPV) mechanisms & a breeze power mechanism, which are connected with the utilities network. in order to optimize the amount of electricity generated within various environmental circumstances, both solar photovoltaic (SPV) & wind energy plants are regulated using a Maximal power point Tracker (MPPT) method of the Perturb & Observation (P&O) kind. A sinusoidal modulation indicate is produced using electricity & voltage regulators relying on the Proportion Integration (PI) method. In addition, the objective of compensating for reactive energy is accomplished by attaching a Distribution Static Synchronous Compensation (D-STATCOM) at the attachment site. The adoption of this technology aids in the maintenance of a reliable utility-grid connections & the effective allocation of energy. Modeling experiments demonstrate that harmonics are diminished at many connections sites & remain below five percent, in accordance with the International Electrical & Electronic-519 specification. It guarantees optimal performance of the suggested system by considering variations in solar photovoltaic (SPV) radiation & wind velocity. Further- more, the steady-state responsiveness of the created computer is achieved by implementing a Proportion Integration controller & subsequently examined. The resulting findings are contrasted using the Grasshopper Optimization (GO) method to ensure validity & correctness. The GO approach yields rising time, settlement period, & maximal overshoot values of 0.246 s, 0.38 s, & six percent, respectfully. Thus, it is anticipated that the implementation of Distribution Static Synchronous Compensation with GO method is effectively integrated with the capability of resolving significant power quality concerns, such as current & electricity profiles, among others. In summary, the findings indicate that the suggested approach is exceptionally effective, rendering it a perfect option for rural towns aiming to embrace green energy remedies.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/i3ceet61722.2024.10994137
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid Connected Hybrid System Power Quality Examination

Kanhaiya Kumar, B Rajanarayan Prusty, Ankit D. Patel
Power Quality and Harmonics
article

Grid Connected Hybrid System Power Quality Examination

Kanhaiya Kumar, B Rajanarayan Prusty, Ankit D. Patel
article en

Abstract

This study investigates the oversight technique & simulation of a combination system which includes (SPV) mechanisms & a breeze power mechanism, which are connected with the utilities network. in order to optimize the amount of electricity generated within various environmental circumstances, both solar photovoltaic (SPV) & wind energy plants are regulated using a Maximal power point Tracker (MPPT) method of the Perturb & Observation (P&O) kind. A sinusoidal modulation indicate is produced using electricity & voltage regulators relying on the Proportion Integration (PI) method. In addition, the objective of compensating for reactive energy is accomplished by attaching a Distribution Static Synchronous Compensation (D-STATCOM) at the attachment site. The adoption of this technology aids in the maintenance of a reliable utility-grid connections & the effective allocation of energy. Modeling experiments demonstrate that harmonics are diminished at many connections sites & remain below five percent, in accordance with the International Electrical & Electronic-519 specification. It guarantees optimal performance of the suggested system by considering variations in solar photovoltaic (SPV) radiation & wind velocity. Further- more, the steady-state responsiveness of the created computer is achieved by implementing a Proportion Integration controller & subsequently examined. The resulting findings are contrasted using the Grasshopper Optimization (GO) method to ensure validity & correctness. The GO approach yields rising time, settlement period, & maximal overshoot values of 0.246 s, 0.38 s, & six percent, respectfully. Thus, it is anticipated that the implementation of Distribution Static Synchronous Compensation with GO method is effectively integrated with the capability of resolving significant power quality concerns, such as current & electricity profiles, among others. In summary, the findings indicate that the suggested approach is exceptionally effective, rendering it a perfect option for rural towns aiming to embrace green energy remedies.

Galgotias University (IN)
Affordable and clean energy
Openalex Percentile: Top 72%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.