Detection and Location of Myocardial Infarction Using Electrocardiogram: Validation by Cardiovascular Magnetic Resonance Imaging

Abstract Background In the assessment of ischemic heart disease, cardiac magnetic resonance (CMR) is considered the gold standard for detecting and locating myocardial infarction (MI), but electrocardiogram (ECG) is less expensive and more widely available. Recognition of MI on ECG outside the acute phase is challenging; Q waves are absent in a significant proportion of patients and may reduce or disappear over time. Although ECG is widely used in the initial assessment of previous infarction, studies to validate ECG using CMR as a reference in the context of chronic coronary disease are limited. Objectives To evaluate the diagnostic performance of ECG in detecting and locating CMR-defined MI. Methods This study included 352 individuals who underwent CMR and ECG, 241 patients with previous MI confirmed by CMR and 111 controls with normal CMR. Their ECG tracings were analyzed by 2 observers, who were blinded to the CMR, for detection and location of MI following to the Fourth Brazilian Society of Cardiology Guidelines on the Analysis and Issuance of Electrocardiographic Reports. The significance level adopted was 5% (p < 0.05). Results ECG showed good performance for detecting previous MI, with sensitivity of 69.3% (64.5% to 74.1%), specificity of 99.1% (98.1% to 100%), and accuracy of 78.7% (74.4% to 83.0%). However, in locating MI in accordance with CMR, its accuracy was unsatisfactory. Conclusions When compared to CMR, ECG was shown to be a method with good accuracy for detecting previous MI, but not for defining its location.

Authors

Institutions

Publication Details

Journal
Arquivos Brasileiros de Cardiologia
Published
2025-03-01
DOI
https://doi.org/10.36660/abc.20240309i
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and Location of Myocardial Infarction Using Electrocardiogram: Validation by Cardiovascular Magnetic Resonance Imaging

Guilherme Garcia, Nevelton Heringer Filho, Rafael Almeida Fonseca, Martina Guerra et al.
Arquivos Brasileiros de Cardiologia
Cardiac Imaging and Diagnostics
article

Detection and Location of Myocardial Infarction Using Electrocardiogram: Validation by Cardiovascular Magnetic Resonance Imaging

Guilherme Garcia, Nevelton Heringer Filho, Rafael Almeida Fonseca, Martina Guerra, Augusto Hiroshi Uchida, William Azem Chalela, Carlos Eduardo Rochitte, Ulísses Ramos Montarroyos, André Gustavo da Silva Rezende, Jürgen Beuther, Eduardo Cavalcanti Lapa Santos, Tiago Augusto Magalhães, Renata Ávila Cintra, José Antônio Franchine Ramires
article en

Abstract

Abstract Background In the assessment of ischemic heart disease, cardiac magnetic resonance (CMR) is considered the gold standard for detecting and locating myocardial infarction (MI), but electrocardiogram (ECG) is less expensive and more widely available. Recognition of MI on ECG outside the acute phase is challenging; Q waves are absent in a significant proportion of patients and may reduce or disappear over time. Although ECG is widely used in the initial assessment of previous infarction, studies to validate ECG using CMR as a reference in the context of chronic coronary disease are limited. Objectives To evaluate the diagnostic performance of ECG in detecting and locating CMR-defined MI. Methods This study included 352 individuals who underwent CMR and ECG, 241 patients with previous MI confirmed by CMR and 111 controls with normal CMR. Their ECG tracings were analyzed by 2 observers, who were blinded to the CMR, for detection and location of MI following to the Fourth Brazilian Society of Cardiology Guidelines on the Analysis and Issuance of Electrocardiographic Reports. The significance level adopted was 5% (p < 0.05). Results ECG showed good performance for detecting previous MI, with sensitivity of 69.3% (64.5% to 74.1%), specificity of 99.1% (98.1% to 100%), and accuracy of 78.7% (74.4% to 83.0%). However, in locating MI in accordance with CMR, its accuracy was unsatisfactory. Conclusions When compared to CMR, ECG was shown to be a method with good accuracy for detecting previous MI, but not for defining its location.

Arquivos Brasileiros de CardiologiaVol. 122(3)
Universidade de São Paulo (BR), Universidade Federal de Pernambuco (BR), Hospital Israelita Albert Einstein (BR), Universidade Brasil (BR), Hospital de l'Esperança (ES), Hospital do Coração (BR), Universidade Federal do Paraná (BR), Universidade de Pernambuco (BR)
Openalex Percentile: Top 84%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.