Purpose: Manual contouring of organs-at-risk (OARs) in radiotherapy planning is a time-consuming and labor-intensive task that is prone to inter- and intra-observer variabilities. Additionally, contours drawn prior to treatment may not accurately reflect the patient’s anatomy throughout the entire treatment course, meaning that doses planned based on pre-treatment contours may not correspond to the actual delivered doses. This study seeks to explore the impact of OAR contour accuracy on prostate radiotherapy outcomes. Methods: OARs (bladder and rectum) were manually delineated on planning CT and daily CBCT images for 20 patients. Atlas-based segmentation algorithms were used to automatically generate OAR contours on the planning CT scans. Both low-risk (LRP, CTV = Prostate) and intermediate-risk (IRP, CTV = Prostate+SV) patient groups were simulated. Treatment plans were created via a novel automated planning application that utilized a knowledge-based planning solution for both auto-generated OARs (aOAR-plan) and manual delineated OARs (mOAR-plan). Planned doses were transferred from CT to CBCTs based on clinical shifts, and contour-based deformable registrations were applied to calculate the cumulative doses. Cumulative dose differences for OARs were used to assess the agreement between aOAR- and mOAR-plans. Additionally, five patients were selected to compare the cumulative dose differences between the transferred and re-calculated doses on CBCT. Results: The Overlap index/Dice similarity coefficient between auto- and manual-contours was 0.89 ± 0.10/0.77 ± 0.11 for the bladder and 0.76 ± 0.15/0.70 ± 0.07 for the rectum. Both LRP and IRP groups demonstrated good dosimetric agreements between aOAR- and mOAR-plans. No significant OAR dose differences between the transferred and re-calculated doses were observed. Conclusion: Contours manually drawn prior to treatment are being used to represent patient anatomy that can fluctuate by several millimeters daily, which raises questions about the time and effort involved. Automated contouring tools enhance contour consistency and deliver acceptable doses, providing a more reliable alternative to manual contours in prostate radiotherapy.

Authors

Institutions

Publication Details

Journal
International Journal of Medical Physics Clinical Engineering and Radiation Oncology
Published
2025-01-01
DOI
https://doi.org/10.4236/ijmpcero.2025.142005
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Are Auto-Generated Organ-at-Risk Contours Good Enough in Prostate Radiotherapy?

B Sintay, D Wiant, Han Liu
International Journal of Medical Physics Clinical Engineering and Radiation Oncology
Advanced Radiotherapy Techniques
article

Are Auto-Generated Organ-at-Risk Contours Good Enough in Prostate Radiotherapy?

B Sintay, D Wiant, Han Liu
article en

Abstract

Purpose: Manual contouring of organs-at-risk (OARs) in radiotherapy planning is a time-consuming and labor-intensive task that is prone to inter- and intra-observer variabilities. Additionally, contours drawn prior to treatment may not accurately reflect the patient’s anatomy throughout the entire treatment course, meaning that doses planned based on pre-treatment contours may not correspond to the actual delivered doses. This study seeks to explore the impact of OAR contour accuracy on prostate radiotherapy outcomes. Methods: OARs (bladder and rectum) were manually delineated on planning CT and daily CBCT images for 20 patients. Atlas-based segmentation algorithms were used to automatically generate OAR contours on the planning CT scans. Both low-risk (LRP, CTV = Prostate) and intermediate-risk (IRP, CTV = Prostate+SV) patient groups were simulated. Treatment plans were created via a novel automated planning application that utilized a knowledge-based planning solution for both auto-generated OARs (aOAR-plan) and manual delineated OARs (mOAR-plan). Planned doses were transferred from CT to CBCTs based on clinical shifts, and contour-based deformable registrations were applied to calculate the cumulative doses. Cumulative dose differences for OARs were used to assess the agreement between aOAR- and mOAR-plans. Additionally, five patients were selected to compare the cumulative dose differences between the transferred and re-calculated doses on CBCT. Results: The Overlap index/Dice similarity coefficient between auto- and manual-contours was 0.89 ± 0.10/0.77 ± 0.11 for the bladder and 0.76 ± 0.15/0.70 ± 0.07 for the rectum. Both LRP and IRP groups demonstrated good dosimetric agreements between aOAR- and mOAR-plans. No significant OAR dose differences between the transferred and re-calculated doses were observed. Conclusion: Contours manually drawn prior to treatment are being used to represent patient anatomy that can fluctuate by several millimeters daily, which raises questions about the time and effort involved. Automated contouring tools enhance contour consistency and deliver acceptable doses, providing a more reliable alternative to manual contours in prostate radiotherapy.

International Journal of Medical Physics Clinical Engineering and Radiation OncologyVol. 14(02)
Cone Health (US)
Varian Medical Systems
Openalex Percentile: Top 88%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.