Dosimetric Comparison with Different ARC and Beam VMAT Optimization in the Monaco Treatment Planning System

Introduction: The Monaco Treatment planning system provides the sequencing parameter ‘Max Number of Arcs’ in volumetric modulated arc therapy optimization. Using this, we can have a maximum of four arcs per beam. In this study, different arc and beam combinations are evaluated. Aim: To compare the dosimetric parameters of VMAT plans in oral cavity radiotherapy treatment planning using single beam multiple arcs and two beam single arcs, and thereby evaluate the effects of the ‘Max Number of Arcs’ optimization parameter in the Monaco treatment planning system. Materials and methods: Data from 10 previously treated head and neck cancer (oral cavity) patients were used for this study. For each patient, four plans were generated with different arc and beam arrangements (one beam with 4 arcs, one beam with 3 arcs, one beam with 2 arcs, and two beams with a single arc). Plans were generated with similar constraints and dose coverage objectives, and all plans were normalized to receive 95% of the PTV receiving 100% of the prescription dose. Plans were evaluated using different dosimetric parameters. Results and discussion: Using one beam with four arc optimization parameter, homogeneous plans were generated, compromising delivery time and MU. One beam three arc plan gives comparative dose coverage, reduced delivery time, and MU compared to one beam four arc plan. One beam with two arc shows poor coverage. Two beam, one arc doesn’t give the expected result with a higher Dmax value, but MU and delivery times are on par with the three beam, one arc plan. Conclusion: For complex head and neck plans, one beam with three arcs is recommended for obtaining the optimum dose coverage, delivery time, and MU. This leads to reduced patient-on-table time and quality assurance time.

Authors

Institutions

Publication Details

Journal
Asian Pacific Journal of Cancer Care
Published
2025-04-16
DOI
https://doi.org/10.31557/apjcc.2025.10.2.393-398
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Comparison with Different ARC and Beam VMAT Optimization in the Monaco Treatment Planning System

Maya Padmanabhan, Наталья Сенина, Resmi K Bharathan, Silpa Ajay Kumar et al.
1 citations
Asian Pacific Journal of Cancer Care
Advanced Radiotherapy Techniques
1.88
article

Dosimetric Comparison with Different ARC and Beam VMAT Optimization in the Monaco Treatment Planning System

Maya Padmanabhan, Наталья Сенина, Resmi K Bharathan, Silpa Ajay Kumar, L. Jose, M Aiswarya., Greeshma K.E
article en
1 citations

Abstract

Introduction: The Monaco Treatment planning system provides the sequencing parameter ‘Max Number of Arcs’ in volumetric modulated arc therapy optimization. Using this, we can have a maximum of four arcs per beam. In this study, different arc and beam combinations are evaluated. Aim: To compare the dosimetric parameters of VMAT plans in oral cavity radiotherapy treatment planning using single beam multiple arcs and two beam single arcs, and thereby evaluate the effects of the ‘Max Number of Arcs’ optimization parameter in the Monaco treatment planning system. Materials and methods: Data from 10 previously treated head and neck cancer (oral cavity) patients were used for this study. For each patient, four plans were generated with different arc and beam arrangements (one beam with 4 arcs, one beam with 3 arcs, one beam with 2 arcs, and two beams with a single arc). Plans were generated with similar constraints and dose coverage objectives, and all plans were normalized to receive 95% of the PTV receiving 100% of the prescription dose. Plans were evaluated using different dosimetric parameters. Results and discussion: Using one beam with four arc optimization parameter, homogeneous plans were generated, compromising delivery time and MU. One beam three arc plan gives comparative dose coverage, reduced delivery time, and MU compared to one beam four arc plan. One beam with two arc shows poor coverage. Two beam, one arc doesn’t give the expected result with a higher Dmax value, but MU and delivery times are on par with the three beam, one arc plan. Conclusion: For complex head and neck plans, one beam with three arcs is recommended for obtaining the optimum dose coverage, delivery time, and MU. This leads to reduced patient-on-table time and quality assurance time.

Asian Pacific Journal of Cancer CareVol. 10(2)
Malabar Cancer Centre (IN)
Openalex Percentile: Top 17%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.