Photogrammetric image processing and comparison of experimental result with laser diffraction and the PDA method

Optical methods have been established as a standard tool for aerosol size measurement. The aim of this paper is to compare the results of two commercial optical instruments based on Phase Doppler Anemometry (PDA) and Laser Diffraction (LD) with an in-house optical photogrammetric measurement method. For the purpose of this comparison, a new in-house image processing procedure was developed with the use of a MATLAB script. The accuracy of the method was tested on several calibration particle samples as well as on PDA and LD commercial instruments. The analysis of the measurements with calibration standard particles was done using the Bias-Variance decomposition method. All three methods were tested on the polydisperse sand particle sample. The results are applicable to determine the benefits and drawbacks of these methods in their application to the broader field of aerosol technology.

Authors

Institutions

Publication Details

Journal
Acta Polytechnica
Published
2025-05-07
DOI
https://doi.org/10.14311/ap.2025.65.0177
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photogrammetric image processing and comparison of experimental result with laser diffraction and the PDA method

Adam Huněk, Ondřej Bartoš
Acta Polytechnica
Optical measurement and interference techniques
article

Photogrammetric image processing and comparison of experimental result with laser diffraction and the PDA method

Adam Huněk, Ondřej Bartoš
article en

Abstract

Optical methods have been established as a standard tool for aerosol size measurement. The aim of this paper is to compare the results of two commercial optical instruments based on Phase Doppler Anemometry (PDA) and Laser Diffraction (LD) with an in-house optical photogrammetric measurement method. For the purpose of this comparison, a new in-house image processing procedure was developed with the use of a MATLAB script. The accuracy of the method was tested on several calibration particle samples as well as on PDA and LD commercial instruments. The analysis of the measurements with calibration standard particles was done using the Bias-Variance decomposition method. All three methods were tested on the polydisperse sand particle sample. The results are applicable to determine the benefits and drawbacks of these methods in their application to the broader field of aerosol technology.

Acta PolytechnicaVol. 65(2)
Czech Technical University in Prague (CZ)
Grantová Agentura České Republiky
Openalex Percentile: Top 92%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.