Parameter Choices in Haarpsi for IQA with Medical Images

When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often-overlooked problem regarding suitability. In previous studies, the FR-IQA measure HaarPSI showed promising behavior for natural and medical images. The measure is based on Haar wavelet representations and the framework allows optimization of two parameters. So far, these parameters have been aligned for natural images. Here, we optimize these parameters for two medical image data sets, a photoacoustic and a chest X-ray data set, with IQA expert ratings. We observe that they lead to similar parameter values and are more sensitive to parameter changes compared to natural image data. We denote the novel optimized setting as <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{HaarPSI}_{MED}$</tex>, which improves the performance of the employed medical images significantly (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$p&lt; 0.05$</tex>). Additionally, we include an inde-pendent CT test data set that illustrates the generalizability of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{HaarPSI}_{MED}$</tex>, as well as visual examples that qualitatively demonstrate the improvement. The results suggest that adapting common IQA measures within their frameworks for medical images can provide a valuable, generalizable addition to employment of more specific task-based measures.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10981227
Citations
3
Primary Topic
Generative Adversarial Networks and Image Synthesis
Type
article
Field-Weighted Citation Impact
3.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameter Choices in Haarpsi for IQA with Medical Images

Judith Babar, Timothy J Sadler, Carola‐Bibiane Schönlieb, Jake Beckford et al.
3 citations
Generative Adversarial Networks and Image Synthesis
3.83
article

Parameter Choices in Haarpsi for IQA with Medical Images

Judith Babar, Timothy J Sadler, Carola‐Bibiane Schönlieb, Jake Beckford, Anna Breger, Thomas R. Else, Jonathan Richard Weir-McCall, Michael S. Roberts, Ian Selby, James H.F. Rudd, Janek Gröhl, Clemens Karner, Shahab Shahipasand, Arthikkaa Thavakumar
article en
3 citations

Abstract

When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often-overlooked problem regarding suitability. In previous studies, the FR-IQA measure HaarPSI showed promising behavior for natural and medical images. The measure is based on Haar wavelet representations and the framework allows optimization of two parameters. So far, these parameters have been aligned for natural images. Here, we optimize these parameters for two medical image data sets, a photoacoustic and a chest X-ray data set, with IQA expert ratings. We observe that they lead to similar parameter values and are more sensitive to parameter changes compared to natural image data. We denote the novel optimized setting as <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{HaarPSI}_{MED}$</tex>, which improves the performance of the employed medical images significantly (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$p&lt; 0.05$</tex>). Additionally, we include an inde-pendent CT test data set that illustrates the generalizability of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{HaarPSI}_{MED}$</tex>, as well as visual examples that qualitatively demonstrate the improvement. The results suggest that adapting common IQA measures within their frameworks for medical images can provide a valuable, generalizable addition to employment of more specific task-based measures.

King's College London (GB), University of Cambridge (GB), Cambridge University Hospitals NHS Foundation Trust (GB), Medical University of Vienna (AT)
Openalex Percentile: Top 7%
Generative Adversarial Networks and Image Synthesis
3.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.