Swin-Kat: Advancing Swin Transformer with Kolmogorov-Arnold Network for CT Image Quality Assessment

Accurate and reliable image quality assessment (IQA) plays a pivotal role in optimizing clinical diagnosis. Most of the existing deep learning models depend on proxy IQA scores of radiologists' assessments and rely on complex architectures demanding significant computational resources. However, proxy scores may not always align well with the diagnostic quality followed by clinicians, and the complex framework limits real-time application and scalability on standard clinical hardware. In this paper, we propose a novel reference-free, automated and reliable computed tomography (CT) IQA model employing a Kolmogorov-Arnold Network-based transformer framework with an attention mechanism, dubbed Swin-KAT. Extensive evaluations demonstrate the effectiveness of the proposed Swin-Kat not only in accurately predicting in-domain radiologists' assessment but also in evaluating out-of-domain clinical images of pediatric CT exams. Furthermore, Swin-KAT is capable of quantifying the quality of approximately 50 CT images per second with minimal memory consumption, outperforming existing CT IQA methods. Our code is available at this link.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10981172
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Swin-Kat: Advancing Swin Transformer with Kolmogorov-Arnold Network for CT Image Quality Assessment

Jie Zhang, Abdullah-Al-Zubaer Imran, Kazi Ramisa Rifa
Advanced X-ray and CT Imaging
article

Swin-Kat: Advancing Swin Transformer with Kolmogorov-Arnold Network for CT Image Quality Assessment

Jie Zhang, Abdullah-Al-Zubaer Imran, Kazi Ramisa Rifa
article en

Abstract

Accurate and reliable image quality assessment (IQA) plays a pivotal role in optimizing clinical diagnosis. Most of the existing deep learning models depend on proxy IQA scores of radiologists' assessments and rely on complex architectures demanding significant computational resources. However, proxy scores may not always align well with the diagnostic quality followed by clinicians, and the complex framework limits real-time application and scalability on standard clinical hardware. In this paper, we propose a novel reference-free, automated and reliable computed tomography (CT) IQA model employing a Kolmogorov-Arnold Network-based transformer framework with an attention mechanism, dubbed Swin-KAT. Extensive evaluations demonstrate the effectiveness of the proposed Swin-Kat not only in accurately predicting in-domain radiologists' assessment but also in evaluating out-of-domain clinical images of pediatric CT exams. Furthermore, Swin-KAT is capable of quantifying the quality of approximately 50 CT images per second with minimal memory consumption, outperforming existing CT IQA methods. Our code is available at this link.

University of Kentucky (US)
Openalex Percentile: Top 90%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.