Real-Time Image Reconstruction with Deep Denoising for Low-Field MRI-Guided Interventions

Congenital heart disease (CHD) affects thousands of infants annually, often necessitating repeated catheterizations guided by X-ray fluoroscopy, leading to cumulative radiation exposure. Low-field MRI guided intervention can reduce this risk; however, image noise is problematic. To reduce this risk, We present a real-time image reconstruction pipeline for low-field (0.55T) Magnetic Resonance Imaging (MRI)-guided interventions, using a 0.55T MRI scanner. Our method integrates the GRAPPA with a modified DnCNN denoising network in a deep learning framework, achieving high-quality, low-latency image reconstructions. The proposed pipeline was validated in preclinical in vivo experiments, demonstrating a 15% improvement in signal-to-noise ratio (SNR) and a 30% reduction in image artifacts compared to conventional techniques, while maintaining real-time performance.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10980690
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Image Reconstruction with Deep Denoising for Low-Field MRI-Guided Interventions

Orlando P. Simonetti, Yuan Xue, Aimee K. Armstrong, Kelvin Chow et al.
Advanced MRI Techniques and Applications
article

Real-Time Image Reconstruction with Deep Denoising for Low-Field MRI-Guided Interventions

Orlando P. Simonetti, Yuan Xue, Aimee K. Armstrong, Kelvin Chow, Rizwan Ahmad, Yingmin Liu, Axel J. Krafft, Yixuan Liu, Chong Chen, Ning Jin, Yu Ding, Florian Maier
article en

Abstract

Congenital heart disease (CHD) affects thousands of infants annually, often necessitating repeated catheterizations guided by X-ray fluoroscopy, leading to cumulative radiation exposure. Low-field MRI guided intervention can reduce this risk; however, image noise is problematic. To reduce this risk, We present a real-time image reconstruction pipeline for low-field (0.55T) Magnetic Resonance Imaging (MRI)-guided interventions, using a 0.55T MRI scanner. Our method integrates the GRAPPA with a modified DnCNN denoising network in a deep learning framework, achieving high-quality, low-latency image reconstructions. The proposed pipeline was validated in preclinical in vivo experiments, demonstrating a 15% improvement in signal-to-noise ratio (SNR) and a 30% reduction in image artifacts compared to conventional techniques, while maintaining real-time performance.

Siemens Healthcare (United States) (US), The Ohio State University (US)
American Heart Association, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 85%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-Time Image Reconstruction with Deep Denoising for Low-Field MRI-Guided Interventions — Orlando P. Simonetti, Yuan Xue, et al. · (2025) | TGRS Research Map | TGRS