Optimization-Based Motion Estimation in HR-PQCT

The imaging modality high-resolution peripheral quantitative computed tomography (HR-pQCT) enables assessment of bone mineral density and three-dimensional microarchitecture of peripheral limbs. Due to its long scan time, this modality is especially susceptible towards motion of the patient. The architecture and scanning protocol of existing scanners, which acquire only halfscans, make many existing methods of motion compensation inapplicable. In this work, an iterative motion estimation and compensation approach is proposed that is able to significantly reduce the amount of motion artifacts. This is achieved by jointly optimizing the motion parameters and reference image to minimize the data consistency error by exploiting the quasi-convex behavior of the objective functions observed near the ground truth. The proposed method was evaluated on a large collection of simulated sinograms and was able to remove motion artifacts almost completely.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10981281
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization-Based Motion Estimation in HR-PQCT

Björn Busse, Marija Boberg, Tobias A. Knopp, Felix N von Brackel et al.
Medical Imaging and Analysis
article

Optimization-Based Motion Estimation in HR-PQCT

Björn Busse, Marija Boberg, Tobias A. Knopp, Felix N von Brackel, Paul Jürß
article en

Abstract

The imaging modality high-resolution peripheral quantitative computed tomography (HR-pQCT) enables assessment of bone mineral density and three-dimensional microarchitecture of peripheral limbs. Due to its long scan time, this modality is especially susceptible towards motion of the patient. The architecture and scanning protocol of existing scanners, which acquire only halfscans, make many existing methods of motion compensation inapplicable. In this work, an iterative motion estimation and compensation approach is proposed that is able to significantly reduce the amount of motion artifacts. This is achieved by jointly optimizing the motion parameters and reference image to minimize the data consistency error by exploiting the quasi-convex behavior of the objective functions observed near the ground truth. The proposed method was evaluated on a large collection of simulated sinograms and was able to remove motion artifacts almost completely.

Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE), Hamburg University of Technology (DE)
Openalex Percentile: Top 90%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.