Non-Invasive Cuffless Bioimpedance System for Measuring Brachial-Ankle Pulse Wave Velocity

This article presents a new cuffless bioimpedance method designed to measure brachial-ankle pulse wave velocity (baPWV), an important indicator of arterial stiffness and cardiovascular risk. The suggested approach detects dynamic impedance changes in body tissue caused by blood flow pulses. Tests showed strong correlation between the new bioimpedance device and traditional cuff-based methods. However, absolute pulse transit times were longer because the ECG R-peak was used as a timing reference, and the inflection point of the pulse wave was selected instead of its onset. Despite this, the differences in transit time measurements were consistent and reliable. The results demonstrate that this novel cuffless bioimpedance system has potential for use in clinical environments, offering more comfort for patients and broader applicability.

Authors

Institutions

Publication Details

Published
2025-04-08
DOI
https://doi.org/10.1109/reepe63962.2025.10971124
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Cuffless Bioimpedance System for Measuring Brachial-Ankle Pulse Wave Velocity

A. E. Pokrovskaya, T. A. Safronova, Amaliya latypova, Ahmad Hammoud et al.
Tendon Structure and Treatment
article

Non-Invasive Cuffless Bioimpedance System for Measuring Brachial-Ankle Pulse Wave Velocity

A. E. Pokrovskaya, T. A. Safronova, Amaliya latypova, Ahmad Hammoud, S. V. Tangatarova, J.S. Evdokimova
article en

Abstract

This article presents a new cuffless bioimpedance method designed to measure brachial-ankle pulse wave velocity (baPWV), an important indicator of arterial stiffness and cardiovascular risk. The suggested approach detects dynamic impedance changes in body tissue caused by blood flow pulses. Tests showed strong correlation between the new bioimpedance device and traditional cuff-based methods. However, absolute pulse transit times were longer because the ECG R-peak was used as a timing reference, and the inflection point of the pulse wave was selected instead of its onset. Despite this, the differences in transit time measurements were consistent and reliable. The results demonstrate that this novel cuffless bioimpedance system has potential for use in clinical environments, offering more comfort for patients and broader applicability.

Bauman Moscow State Technical University (RU), Sechenov University (RU)
Zero hunger
Openalex Percentile: Top 87%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.