Enhanced Control for Power Quality Improvement in Three-Phase Grid Tied PV System

This article provides a technique for mitigating harmonics and load sharing in a grid interfaced PV system, both when the system is under load and when it is not, by using an improved feed forward decoupling (FFD) control-based Grid linked inverter control technique. In order to keep the dc link voltage stable, a fuzzy based Proportionalintegral-derivative (FLPID) controller is used. The suggested FPID-FFD control strategy consists of three loops: an MPPT loop, an external DC voltage loop, and an internal AC current loop. To maximize the output of a PV system, perturb and observe (P&O) is utilized. This method of control is not only effective in decoupling active and reactive power, but it is also easy to use and produces precise results. Both under load and without load, the suggested control technique exhibits satisfactory behavior in terms of eliminating harmonics. The suggested FLPID-FFD control technique is tested in matlab/Simulink with varying levels of irradiance. The archived results are found satisfactorily and are meeting within the IEEE-519 norms.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1109/iciccs65191.2025.10984955
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Control for Power Quality Improvement in Three-Phase Grid Tied PV System

Pragna Rao, Kumarraja Andanapalli, Murali Krishna, Sasi Chinnathambi et al.
Power Systems and Renewable Energy
article

Enhanced Control for Power Quality Improvement in Three-Phase Grid Tied PV System

Pragna Rao, Kumarraja Andanapalli, Murali Krishna, Sasi Chinnathambi, D. Anantha Koteswararao Rao, S Reddy
article en

Abstract

This article provides a technique for mitigating harmonics and load sharing in a grid interfaced PV system, both when the system is under load and when it is not, by using an improved feed forward decoupling (FFD) control-based Grid linked inverter control technique. In order to keep the dc link voltage stable, a fuzzy based Proportionalintegral-derivative (FLPID) controller is used. The suggested FPID-FFD control strategy consists of three loops: an MPPT loop, an external DC voltage loop, and an internal AC current loop. To maximize the output of a PV system, perturb and observe (P&O) is utilized. This method of control is not only effective in decoupling active and reactive power, but it is also easy to use and produces precise results. Both under load and without load, the suggested control technique exhibits satisfactory behavior in terms of eliminating harmonics. The suggested FLPID-FFD control technique is tested in matlab/Simulink with varying levels of irradiance. The archived results are found satisfactorily and are meeting within the IEEE-519 norms.

Annamalai University (IN), SRKR Engineering College
Affordable and clean energy
Openalex Percentile: Top 92%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Control for Power Quality Improvement in Three-Phase Grid Tied PV System — Pragna Rao, Kumarraja Andanapalli, et al. · (2025) | TGRS Research Map | TGRS