A Method for Load Synchronization Detection of Power Secondary Cables Based on BeiDou Timing Data

Conventional power secondary cable load synchronization detection method is based on the load frequency band characterization, and does not take into account the influence of harmonic interference, and the detection results are biased. Therefore, a power secondary cable load synchronization detection method based on Beidou timing data is designed. Detecting the load synchronization variable time sequence of power secondary cable, detecting the load abnormality of a continuous univariate or multivariate time sequence, ensuring the comprehensiveness of load detection. Based on the BeiDou time series data synchronization to locate the abnormal load interval of the secondary cable, using the signal of BeiDou satellite navigation system, the scattering parameters of the secondary cable are determined, and they are used as the observation quantity of the abnormal load combination to avoid the problem of the load synchronization detection error. Using comparative experiments, it is verified that the method has better quality of synchronous detection and can be applied in real life.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/icsgge64667.2025.10984456
Citations
1
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Method for Load Synchronization Detection of Power Secondary Cables Based on BeiDou Timing Data

Liming Zheng, Wenfei Zhang, Hui Kang, Wei Wang et al.
1 citations
Power Systems and Technologies
0.73
article

A Method for Load Synchronization Detection of Power Secondary Cables Based on BeiDou Timing Data

Liming Zheng, Wenfei Zhang, Hui Kang, Wei Wang, Zhenxing Yun, Zhirong Zhang, Fulai Yu
article en
1 citations

Abstract

Conventional power secondary cable load synchronization detection method is based on the load frequency band characterization, and does not take into account the influence of harmonic interference, and the detection results are biased. Therefore, a power secondary cable load synchronization detection method based on Beidou timing data is designed. Detecting the load synchronization variable time sequence of power secondary cable, detecting the load abnormality of a continuous univariate or multivariate time sequence, ensuring the comprehensiveness of load detection. Based on the BeiDou time series data synchronization to locate the abnormal load interval of the secondary cable, using the signal of BeiDou satellite navigation system, the scattering parameters of the secondary cable are determined, and they are used as the observation quantity of the abnormal load combination to avoid the problem of the load synchronization detection error. Using comparative experiments, it is verified that the method has better quality of synchronous detection and can be applied in real life.

State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 29%
Power Systems and Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.