Deuterium Metabolic Imaging Denoising Using a Linear Tangent Space Alignment (LTSA) Model and Performance Analysis

Deuterium metabolic imaging (DMI) is an emerging technique to map metabolism of human body non-invasively. However, conventional DMI acquisition methods are limited by the signal-to-noise ratio (SNR) due to the small gyromagnetic ratio of deuterium and low concentration of deuteriumlabeled metabolites. This work presents a manifold learningbased method that leverages the intrinsic low-dimensional manifold structure of the underlying DMI signals for denoising via a linear tangent space alignment (LTSA) model. Cramer-Rao Lower Bound (CRLB) analysis was performed to characterize the reduction in noise and in the variance of the metabolite concentration estimation achieved by the proposed method, which was validated using numerical simulation studies.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10980807
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deuterium Metabolic Imaging Denoising Using a Linear Tangent Space Alignment (LTSA) Model and Performance Analysis

Didi Chi, Paul Kyu Han, Robin A. de Graaf, Henk M. De Feyter et al.
Medical Imaging Techniques and Applications
article

Deuterium Metabolic Imaging Denoising Using a Linear Tangent Space Alignment (LTSA) Model and Performance Analysis

Didi Chi, Paul Kyu Han, Robin A. de Graaf, Henk M. De Feyter, Chao Ma
article en

Abstract

Deuterium metabolic imaging (DMI) is an emerging technique to map metabolism of human body non-invasively. However, conventional DMI acquisition methods are limited by the signal-to-noise ratio (SNR) due to the small gyromagnetic ratio of deuterium and low concentration of deuteriumlabeled metabolites. This work presents a manifold learningbased method that leverages the intrinsic low-dimensional manifold structure of the underlying DMI signals for denoising via a linear tangent space alignment (LTSA) model. Cramer-Rao Lower Bound (CRLB) analysis was performed to characterize the reduction in noise and in the variance of the metabolite concentration estimation achieved by the proposed method, which was validated using numerical simulation studies.

Yale University (US)
National Institutes of Health
Sustainable cities and communities, Climate action
Openalex Percentile: Top 85%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.