2pCeP<i>d</i>-Net: Two-Path Cross-Context Encoder With Probability Map-Based Bandpass Decoder for Retinal Vessel Segmentation
Accurate automatic retinal blood vessel segmentation in Fundus Images plays an important role in the early diagnosis of any ocular disease detection system. However, most of past literature are yet to attain a superior result primarily due to lack of sufficient annotated data and the complexity in the vessel structure under challenging background conditions. In this work, we propose the design of a Coherence Measure guided Data augmentation model, named as, Lambda-Coherence Measure-guided Cartesian-square (λ<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">CMgC</i><sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>), for enriching the existing datasets with synthetic and structurally coherent fundus images thus alleviating the issue of data scarcity. Subsequently, we propose a novel end-to-end Convolutional network, called two-path Cross-context Encoder with Probability map-based band-pass Decoder (2pCeP<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</i>-Net) for the segmentation of blood vessels endowed with a novel 2<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pCd</i>+ Encoder block with CERg skip connection and a novel ˆ<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pBPf</i> enabled Decoder block. The proposed work has been evaluated using four standard datasets, namely, DRIVE, STARE, CHASEDB1 and HRF and has obtained a benchmark accuracy of 97.6%, 98.1%, 98.2% and 97.7% respectively. Statistically, our proposed model has further achieved benchmark results across Sensitivity, Specificity, F1 and AUC measures of evaluation as well.
Authors
- Mita Nasipuri (ORCID: https://orcid.org/0000-0002-3906-5309)
- Sourav Pramanik (ORCID: https://orcid.org/0000-0002-4006-7483)
- Supratim Ghosh (ORCID: https://orcid.org/0000-0003-1714-5487)
- M. L. KUNDU (ORCID: https://orcid.org/0009-0004-2816-3247)
- Kottakkaran Sooppy Nisar (ORCID: https://orcid.org/0000-0001-5769-4320)
- Anoop Kumar Tiwari (ORCID: https://orcid.org/0000-0001-5368-0351)
Institutions
- Prince Sattam Bin Abdulaziz University (SA)
- Jadavpur University (IN)
- Aliah University (IN)
- Netaji Subhas Open University (IN)
- Netaji Subhas University of Technology (IN)
- Central University of Haryana (IN)
Publication Details
- Journal
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/tim.2025.3569005
- Citations
- 1
- Primary Topic
- Retinal Imaging and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 1.36